Aller au contenu principal
Profil bibliographique

Alice Vuillermoz

Informations fournies par OpenAlex. Research Africa ne déduit ni nationalité, ni poste, ni coordonnées personnelles.

8Publications signalées
80Citations signalées
3Affiliations récentes

Les institutions déclarées

Les domaines associés

Respiratory Support and MechanismsChronic Obstructive Pulmonary Disease (COPD) ResearchAirway Management and Intubation TechniquesNosocomial Infections in ICUEngineering Technology and Methodologies

Les publications récentes

2025 conference-abstract OpenAlex

Performances of surface mechanomyography using a parasternal patch to detect inspiratory effort during spontaneous breathing and mechanical ventilation

Delphine Venkatapen, Marius Lebret, Arnaud Lesimple, M. Lefranc et autres

Background: Monitoring respiratory muscle activity is crucial in respiratory distress. Current methods [esophageal pressure(Pes)/diaphragmatic electrical activity(Eadi)] are invasive and require specialized training. Surface mechanomyography (sMMG) offers a promising non-invasive alternative. Aim: This study evaluated sMMG's effectiveness in detecting inspiratory effort onset compared …

fr (code pays fourni par la source)

0 citations
2024 article OpenAlex

Le recrutement alvéolaire : quels objectifs et quels outils d’évaluation ?

Alice Vuillermoz, Jean-Christophe M. Richard, François Beloncle

Le recrutement alvéolaire correspond à la réouverture de zones parenchymateuses condensées, ce qui permet une augmentation de l’espace alvéolaire disponible aux échanges gazeux et donc une amélioration des rapports ventilation-perfusion. Chez les patients de réanimation ventilés pour un syndrome de détresse respiratoire …

fr, us (code pays fourni par la source)

0 citations Médecine Intensive Réanimation
2024 article OpenAlex

Accuracy of Real-Time Data Provided by Mechanical Insufflation-Exsufflation Devices

Roberto Martínez-Alejos, Emeline Fresnel, Alice Vuillermoz, François Beloncle et autres

Background: Mechanical insufflation-exsufflation (MI-E) is crucial to assist patients with impaired cough, especially those with neuromuscular diseases. Despite recent advancements that enable real-time display of peak expiratory flow (PEF) and inspiratory volume, accurately monitoring these parameters with MI-E devices during treatment can …

es, fr, cz (code pays fourni par la source)

5 citations Respiratory Care
2024 conference-abstract OpenAlex

Accuracy of real-time data provided by mechanical insufflation-exsufflation devices

Roberto Martínez Alejos, Marius Lebret, Alice Vuillermoz, Emeline Fresnel et autres

Mechanical in-exsufflation (MIE) aims to generate cough peak expiratory flows (PEF) similar to those of normal cough. Currently, these devices display PEF and inspiratory volume (Vti) in real time, but there is no data on whether these values correspond to the actual …

fr, at (code pays fourni par la source)

0 citations
Accès ouvert 2024 article OpenAlex

Modes of administration of nitric oxide devices and ventilators flow-by impact the delivery of pre-determined concentrations

Alice Vuillermoz, M. Lefranc, Nathan Prouvez, C. Brault et autres

Nitric oxide (NO) is a strong vasodilator, selectively directed on pulmonary circulation through inhaled administration. In adult intensive care units (ICU), it is mainly used for refractory hypoxemia in mechanically ventilated patients. Several medical delivery devices have been developed to deliver inhaled …

fr (code pays fourni par la source)

5 citations Annals of Intensive Care
Accès ouvert 2023 article OpenAlex

Discussion on Comparison of Four Mechanical Insufflation-Exsufflation Devices: Effect of Simulated Airway Collapse on Cough Peak Flow

Marius Lebret, Alice Vuillermoz, Emeline Fresnel, Alain Mercat et autres

To the Editor: In their recent publication, Terzi et al1 compared the performance of 4 mechanical insufflation-exsufflation (MI-E) devices under 2 airway conditions: stable upper airway (without collapse) and collapsed upper airway simulated using a Starling resistor. The study focused on evaluating …

fr (code pays fourni par la source)

2 citations Respiratory Care
Accès ouvert 2023 article OpenAlex

Performances and limits of Bag-Valve-Device for pre-oxygenation and manual ventilation: A comparative bench and cadaver study

Alexandre Broc, François Morin, Hugo Schmit, Mathilde Taillantou-Candau et autres

Introduction Bag-Valve-Device (BVD) is the most frequently used device for pre-oxygenation and ventilation during cardiopulmonary resuscitation (CPR). A minimal expired fraction of oxygen (FeO 2 ) above 0.85 is recommended during pre-oxygenation while insufflated volume (VTi) should be reduced during manual ventilation. …

fr, ca (code pays fourni par la source)

5 citations Resuscitation
Accès ouvert 2019 article OpenAlex

Accuracy of P0.1 measurements performed by ICU ventilators: a bench study

François Beloncle, Lise Piquilloud, Pierre‐Yves Olivier, Alice Vuillermoz et autres

Occlusion pressure at 100 ms (P0.1), defined as the negative pressure measured 100 ms after the initiation of an inspiratory effort performed against a closed respiratory circuit, has been shown to be well correlated with central respiratory drive and respiratory effort. Automated …

fr, ch (code pays fourni par la source)

63 citations Annals of Intensive Care

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.