2025
conference-abstract
OpenAlex
Delphine Venkatapen, Marius Lebret, Arnaud Lesimple, M. Lefranc et autres
Background: Monitoring respiratory muscle activity is crucial in respiratory distress. Current methods [esophageal pressure(Pes)/diaphragmatic electrical activity(Eadi)] are invasive and require specialized training. Surface mechanomyography (sMMG) offers a promising non-invasive alternative. Aim: This study evaluated sMMG's effectiveness in detecting inspiratory effort onset compared …
fr
(code pays fourni par la source)
2024
article
OpenAlex
Alice Vuillermoz, Jean-Christophe M. Richard, François Beloncle
Le recrutement alvéolaire correspond à la réouverture de zones parenchymateuses condensées, ce qui permet une augmentation de l’espace alvéolaire disponible aux échanges gazeux et donc une amélioration des rapports ventilation-perfusion. Chez les patients de réanimation ventilés pour un syndrome de détresse respiratoire …
fr, us
(code pays fourni par la source)
2024
article
OpenAlex
Roberto Martínez-Alejos, Emeline Fresnel, Alice Vuillermoz, François Beloncle et autres
Background: Mechanical insufflation-exsufflation (MI-E) is crucial to assist patients with impaired cough, especially those with neuromuscular diseases. Despite recent advancements that enable real-time display of peak expiratory flow (PEF) and inspiratory volume, accurately monitoring these parameters with MI-E devices during treatment can …
es, fr, cz
(code pays fourni par la source)
2024
conference-abstract
OpenAlex
Roberto Martínez Alejos, Marius Lebret, Alice Vuillermoz, Emeline Fresnel et autres
Mechanical in-exsufflation (MIE) aims to generate cough peak expiratory flows (PEF) similar to those of normal cough. Currently, these devices display PEF and inspiratory volume (Vti) in real time, but there is no data on whether these values correspond to the actual …
fr, at
(code pays fourni par la source)
Accès ouvert
2024
article
OpenAlex
Alice Vuillermoz, M. Lefranc, Nathan Prouvez, C. Brault et autres
Nitric oxide (NO) is a strong vasodilator, selectively directed on pulmonary circulation through inhaled administration. In adult intensive care units (ICU), it is mainly used for refractory hypoxemia in mechanically ventilated patients. Several medical delivery devices have been developed to deliver inhaled …
fr
(code pays fourni par la source)
Accès ouvert
2023
article
OpenAlex
Marius Lebret, Alice Vuillermoz, Emeline Fresnel, Alain Mercat et autres
To the Editor: In their recent publication, Terzi et al1 compared the performance of 4 mechanical insufflation-exsufflation (MI-E) devices under 2 airway conditions: stable upper airway (without collapse) and collapsed upper airway simulated using a Starling resistor. The study focused on evaluating …
fr
(code pays fourni par la source)
Accès ouvert
2023
article
OpenAlex
Alexandre Broc, François Morin, Hugo Schmit, Mathilde Taillantou-Candau et autres
Introduction Bag-Valve-Device (BVD) is the most frequently used device for pre-oxygenation and ventilation during cardiopulmonary resuscitation (CPR). A minimal expired fraction of oxygen (FeO 2 ) above 0.85 is recommended during pre-oxygenation while insufflated volume (VTi) should be reduced during manual ventilation. …
fr, ca
(code pays fourni par la source)
Accès ouvert
2019
article
OpenAlex
François Beloncle, Lise Piquilloud, Pierre‐Yves Olivier, Alice Vuillermoz et autres
Occlusion pressure at 100 ms (P0.1), defined as the negative pressure measured 100 ms after the initiation of an inspiratory effort performed against a closed respiratory circuit, has been shown to be well correlated with central respiratory drive and respiratory effort. Automated …
fr, ch
(code pays fourni par la source)