Do we need capnogram analysis to guide ventilator settings during pediatric cardiopulmonary resuscitation?
Arnaud Lesimple, Jean-Christophe M. Richard, Domenico L Grieco
gb, fr, it, jp (code pays fourni par la source)
Informations fournies par OpenAlex. Research Africa ne déduit ni nationalité, ni poste, ni coordonnées personnelles.
Arnaud Lesimple, Jean-Christophe M. Richard, Domenico L Grieco
gb, fr, it, jp (code pays fourni par la source)
François Morin, Hugo Schmit, Stefano Malinverni, Laura Polard et autres
Nicolas Segond, Arnaud Lesimple, Lilian Barlet, Laura Polard et autres
Background The impact on ventilation of head and thorax elevation (HTE) and the use of an impedance threshold device (ITD) during cardiopulmonary resuscitation (CPR) remains poorly understood. The aim was to describe the impact on ventilation and absolute lung volumes of HTE …
fr, us, gb, ca (code pays fourni par la source)
Arnaud Lesimple, Jean-Christophe Richard, Fanny Lidouren, Naoto Watanabe et autres
Background The optimal tidal volume (V T ) during Cardio-Pulmonary Resuscitation (CPR) remains unknown. Capnogram could permit to detect ventilation induced harmful effect. Objectives The objectives of the present study were to describe the impact of different V T on hemodynamics during …
fr, ca (code pays fourni par la source)
Jean-Claude Li, Nicolas Segond, Arnaud Lesimple, Alice Hutin et autres
Background Ventilation is a critical determinant of cardiopulmonary resuscitation efficiency. Our goal was to evaluate how ventilatory parameters are reported during cardiopulmonary resuscitation in large animal models of cardiac arrest. Methods A scoping review was conducted following the PRISMA-ScR guidelines, including studies …
fr, gb, ca, it (code pays fourni par la source)
Nicolas Segond, Arnaud Lesimple, Lilian Barlet, Laura Polard et autres
Background: Ventilation during cardiopulmonary resuscitation may affect cardiac arrest management and outcome. Novel strategies such as head and thorax elevation (HTE) and the use of an impedance threshold device (ITD) have been developed to enhance circulation during CPR. However, the impact of …
fr, us (code pays fourni par la source)
Delphine Venkatapen, Marius Lebret, Arnaud Lesimple, M. Lefranc et autres
Background: Monitoring respiratory muscle activity is crucial in respiratory distress. Current methods [esophageal pressure(Pes)/diaphragmatic electrical activity(Eadi)] are invasive and require specialized training. Surface mechanomyography (sMMG) offers a promising non-invasive alternative. Aim: This study evaluated sMMG's effectiveness in detecting inspiratory effort onset compared …
fr (code pays fourni par la source)
Eloïse de Beaufort, Pascale Labedade, M. Lefranc, Mathilde Taillantou-Candau et autres
fr (code pays fourni par la source)
Eloïse de Beaufort, Alice Hutin, Arnaud Lesimple, Lionel Lamhaut et autres
This study investigates the determinants of oxygen consumption in transport ventilators, a critical factor for patient safety, especially during long-distance transfers and in resource-limited settings. A bench study was conducted on 4 ventilators to measure oxygen consumption under various ventilation settings. The …
fr (code pays fourni par la source)
Mattia Docci, François Beloncle, Arnaud Lesimple, Thomas Piraino et autres
Airway closure results in a lack of communication between proximal and distal airways unless the airway pressure (Paw) overcomes the airway opening pressure (AOP). This has been described in patients undergoing mechanical ventilation with acute respiratory distress syndrome, obesity, hydrostatic pulmonary edema …
ca, fr, it, se (code pays fourni par la source)
Alexandre Demoule, Gaëtan Beduneau, Rémi Coudroy, Guillaume Carteaux et autres
Alexandre Demoule, G. Béduneau, Rémi Coudroy, Guillaume Carteaux et autres
BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.
L'essentiel de l'actu tech du Burkina & d'Afrique, chaque semaine dans votre boîte mail.
Gratuit · sans spam · désinscription en un clic