Fractionation increasingly reduces FLASH sparing for acute murine skin damage
Rattachement africain : dk. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
BACKGROUND AND PURPOSE: Preclinical studies report a favourable normal tissue-sparing FLASH effect. Most studies report single-fraction irradiations. The interplay between fractionation and FLASH sparing is highly relevant for clinical translation but is scarce in the literature. This study compared the tissue-sparing effect of FLASH on acute skin toxicity with single-fraction, four-fraction and eight-fraction schemes. MATERIALS AND METHODS: Acute skin toxicity after conventional dose rate (CONV, 0.16 Gy/s) and FLASH (mean ± sd 251 ± 12 Gy/s) irradiation was assessed in female CDF1 mice. The right hindleg of unanaesthetised mice was irradiated using a single dose (1 fraction), one daily dose for four consecutive days (4 fractions) or two daily doses with a 6-hour interval for four consecutive days (8 fractions). The study had 4-12 mice per dose group. The total dose per group ranged from 24.5 to 89.9 Gy. A FLASH-enabled accelerator (TrueBeam, Varian) delivered irradiation with a 16 MeV electron beam. Acute skin toxicity was quantified daily from 9 to 28 days post-treatment. RESULTS: Single-fraction irradiation had a tissue-sparing FLASH effect, which was halved for four fractions and markedly reduced for eight fractions. The dose modification ratio was 1.41 for a single fraction, 1.18 for four fractions, and nonsignificantly 1.05 for eight fractions. CONCLUSION: Fractionation increasingly reduced the acute skin-sparing effect seen in single-fraction FLASH studies. However, a tissue-sparing effect of 18 % was still present at four fractions, while eight fractions provided a nonsignificant 5 % FLASH skin-sparing. Clinical implementation of FLASH may work best in highly hypofractionated settings.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Fractionation increasingly reduces FLASH sparing for acute murine skin damage
- Date Crossref
- 01/12/2025
- Éditeur
- Elsevier BV
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.