Application of a novel anvil holder clamp in laparoscopic gastrectomy
Rattachement africain : cn. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Background: The reverse puncture method is a common reconstruction technique used in radical gastrectomy for gastric cancer. However, its widespread use is limited due to unstable clamping and unstable force directions, which complicate the anastomosis process. Therefore, we aimed to develop an improved clamp and investigated its application during the anastomotic process. Methods: =13), utilizing reverse puncture circular anastomosis techniques during surgery. Intraoperatively, the anterior wall of the esophagus was opened using an anvil holder clamp to position the anvil, and a circular stapler was used to transect the esophagus. Finally, circular anastomosis was completed with assistance from our anvil holder clamp. We assessed the number of clamping attempts, time at each stage, clinical characteristics, and surgical outcomes. Results: All patients underwent successful laparoscopic radical gastrectomy. The mean number of attempts in the two stages was 1.14 and 1.03. The mean duration for these two procedures was 22.6 s and 27.9 s. The overall incidence of postoperative complications (Clavien-Dindo classification grade ≥II) was 17.2%. Esophagojejunostomy leakage occurred in one case (3.4%). Patients with anastomotic leakage were successfully managed with conservative treatment, with no cases of mortality. Conclusion: Our improved clamp is simple, safe, and effective for the anastomotic laparoscopic gastrectomy procedure and may benefit its wide application.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Application of a novel anvil holder clamp in laparoscopic gastrectomy
- Date Crossref
- 01/04/2025
- Éditeur
- Frontiers Media SA
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Shandong Provincial QianFoShan Hospital Department of General Surgery pays non établi dans la noticeÉtablissement de santé
-
Shandong First Medical University Department of General Surgery pays non établi dans la noticeUniversité ou école supérieure
Department of General Surgery — Shandong Provincial QianFoShan Hospital et Department of General Surgery — Shandong First Medical University.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.