Aller au contenu principal
Profil bibliographique

Klaus‐Peter Schmitz

Informations fournies par OpenAlex. Research Africa ne déduit ni nationalité, ni poste, ni coordonnées personnelles.

370Publications signalées
4675Citations signalées
1Affiliations récentes

Les institutions déclarées

Les domaines associés

Coronary Interventions and DiagnosticsCardiac Valve Diseases and TreatmentsElectrospun Nanofibers in Biomedical Applicationsbiodegradable polymer synthesis and propertiesGlaucoma and retinal disorders

Les publications récentes

Accès ouvert 2026 article OpenAlex

Development of a standardized intracranial vessel model from 3D time-of-flight magnetic resonance angiography data of the SHIP cohort

Antonia Dalmer, Stefan Siewert, Dominique Passler, Hagen Paetow et autres

PURPOSE: A standardized, population-based three-dimensional (3D) computer-aided design (CAD) model of the intracranial arterial system was developed from time-of-flight magnetic resonance angiography (TOF-MRA) data of the Study of Health in Pomerania (SHIP) cohort, tailored for realistic simulation and experimental neurovascular applications. METHODS: …

de (code pays fourni par la source)

0 citations Neuroradiology
Accès ouvert 2025 article OpenAlex

Mechanical analysis of braided dissection stents – Influence of stent foreshortening on radial force behaviour

Michael Stiehm, Christoph Brandt-Wunderlich, Arne Briest, Leonard Pitts et autres

Abstract Acute type A aortic dissection (ATAAD) remains a life-threatening condition with high morbidity and mortality rates despite advancements in surgical and perioperative management. The Ascyrus Medical Dissection Stent (AMDS) has been introduced as an adjunct to the hemiarch procedure to reduce …

de (code pays fourni par la source)

0 citations Current Directions in Biomedical Engineering
Accès ouvert 2025 article OpenAlex

Cluster Analysis of Volumetric Calcification Distributions in the Aortic Valve Region of TAVR Patients

Jan Oldenburg, Finja Borowski, Laura Supp, Matthias Leuchter et autres

Abstract Minimally invasive transcatheter aortic valve replacement (TAVR) has become the preferred procedure for patients with aortic valve stenosis or insufficiency who are at high risk for conventional open-heart surgery. The favorable clinical outcomes observed in high-risk patients have led to an …

de (code pays fourni par la source)

0 citations Current Directions in Biomedical Engineering
Accès ouvert 2025 article OpenAlex

Radiopacity of Implants – Micro-CT Compared to Standardized Medical Imaging

W. J. Schmidt, Swen Großmann, Eric Bohne, Peter Behrens et autres

Abstract Radiopacity is an important prerequisite for X-ray visibility of implants. Existing standards refer to the use of Xray systems for medical imaging. Micro Computed Tomography (μCT) technology is available with high resolution imaging. Experimental studies should verify the comparability of radiopacity …

de (code pays fourni par la source)

0 citations Current Directions in Biomedical Engineering
Accès ouvert 2025 article OpenAlex

Analysis of porcine nerves as ex vivo model for upper limb neuro-electrode implantation studies

Vivien Kauschke, Sylvia Pfensig, Valeria Khaimov, Ariane Dierke et autres

Abstract In upper limb amputees implantation of prostheses equipped with electrodes to innervate respective musculature might improve sensitivity and life quality. Besides different types of prostheses being available, there is still a need for devices that provide more comfort and functionality to …

de (code pays fourni par la source)

0 citations Current Directions in Biomedical Engineering
Accès ouvert 2025 article OpenAlex

Laser-induced periodic surface structures for controlled cell growth on vascular stents

Swen Großmann, Rosa Maria Staufer, Niels Grabow, Valeria Khaimov et autres

Abstract Stents play a vital role in the treatment of cardiovascular diseases. In this context, endothelialization is of crucial importance for the final implant performance and the key to an effective treatment. To enhance endothelial cell (EC) attachment and surface coverage, laser-induced …

de (code pays fourni par la source)

0 citations Current Directions in Biomedical Engineering
Accès ouvert 2025 article OpenAlex

In Silico Clinical-Trials: Advancing Validation for Regulatory Approval

Matthias Leuchter, Laura Supp, Jan Oldenburg, Michael Stiehm et autres

Abstract The assesment of the safety and efficacy of medical devices can be time-consuming, expensive, and raise ethical concerns. Additionally, the high costs of innovation and lengthy development times may result in increased prices and unequal access for certain patient groups. In …

de (code pays fourni par la source)

0 citations Current Directions in Biomedical Engineering
Accès ouvert 2025 article OpenAlex

Development of GelMA-Based Hydrogel Scaffolds with Tunable Mechanical Properties for Applications in Peripheral Nerve Regeneration

Klaus‐Peter Schmitz, Tanner L. Larson, Michael W. Borovich, Xianfang Wu et autres

Peripheral nerve injuries (PNIs) have a significant impact on the quality of life for patients suffering from trauma or disease. In injuries with critical nerve gaps, PN regeneration requires tissue scaffolds with appropriate physiological properties that promote cell growth and functions. Hydrogel …

us, se, fr (code pays fourni par la source)

11 citations ACS Biomaterials Science & Engineering
Accès ouvert 2025 article OpenAlex

Impact of calcifications on paravalvular leakage by transcatheter aortic valve prostheses: findings from a new in silico clinical trial framework

Laura Supp, Jan Oldenburg, Matthias Leuchter, Jan Brüning et autres

Transcatheter aortic valve replacement (TAVR) has revolutionized the treatment of severe aortic stenosis, yet paravalvular leakage (PVL) remains a significant complication, associated with increased mortality. Clinical studies have identified correlations between PVL and both anatomical features and calcification patterns. Numerical simulations, particularly …

de, gr, gb (code pays fourni par la source)

2 citations Biomechanics and Modeling in Mechanobiology
Accès ouvert 2025 article OpenAlex

PLLA/PEO blend as self-curing material for a biodegradable Eustachian tube stent

Stefan Oschatz, Selina Schultz, Nicklas Fiedler, Jana Markhoff et autres

Within this work, blending of high molecular weight (HMW) PLLA with HMW polyethylene oxide (PEO) as self-curing biodegradable stent material for potential treatment of Eustachian tube dysfunction (ETD) is reported. Blending with PEO significantly enhances the material’s mechanical properties, enabling the stent …

de (code pays fourni par la source)

4 citations Materials & Design
Accès ouvert 2025 article OpenAlex

Bioprinting of GelMA-Based Hydrogels to Aid in Creation of Biomimetic 3D Models for Glioblastoma

Kaitlyn Ann Rose Schroyer, Klaus‐Peter Schmitz, Gunjeeta Raheja, Bin Su et autres

Glioblastoma (GBM, isocitrate dehydrogenase wild-type) is the most common primary malignant brain tumor in adults and is associated with a severely low survival rate. Treatments offer mere palliation and are ineffective, due, in part, to a lack of understanding of the intricate …

us (code pays fourni par la source)

6 citations Micromachines
Accès ouvert 2024 article OpenAlex

Development of a model system for in vitro simulated application testing of neurovascular stent systems

Stefan Siewert, Christoph Brandt-Wunderlich, Felix Streckenbach, Hagen Paetow et autres

Abstract In vitro test setups for simulated application testing are necessary for physician training as well as for development and benchmarking of various devices in interventional neuroradiology. Within the current study, we implemented a test setup for in vitro simulated application testing. …

de (code pays fourni par la source)

0 citations Current Directions in Biomedical Engineering

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.