THE 10TH INTERNATIONAL CONFERENCE ON X-RAY MICROSCOPY
Ian McNulty, Catherine Eyberger, Barry Lai
Informations fournies par OpenAlex. Research Africa ne déduit ni nationalité, ni poste, ni coordonnées personnelles.
Ian McNulty, Catherine Eyberger, Barry Lai
Motohiro Suzuki, Yuji Kondo, Shinji Isogami, Masakiyo Tsunoda et autres
Artifacts-free lensless on-chip tomography empowered by three-dimensional deconvolution
jp (code pays fourni par la source)
Yoshiji Suzuki, Akihisa Takeuchi, Kentaro Uesugi, Masato Hoshino et autres
Hollow cone illumination optics for imaging x‐ray microscopy in the hard x‐ray region has been developed. The optical system consists of sector condenser zone plate and rotary actuator. The sector condenser zone plate is a combination of periodic transmission gratings, which yields …
jp (code pays fourni par la source)
Yasuko Terada, Hajime Tanida, Tomoya Uruga, Akihisa Takeuchi et autres
An x‐ray microprobe system with total‐reflection mirror optics for trace element analysis has been developed at beamline 37XU of SPring‐8. To achieve sub‐microprobe, a spatial filter has been installed downstream of a monochromator. Focusing tests have been performed in the x‐ray energy …
jp (code pays fourni par la source)
Gregory Denbeaux, Ian McNulty, Catherine Eyberger, Barry Lai
Zone plates as condenser optics for x‐ray microscopes offer simple optical designs for both illumination and spectral resolution when used as a linear monochromator. However, due to the long write times for electron beam lithography, both the availability and the size of …
us (code pays fourni par la source)
T. Rack, Simon Zabler, Alexander Rack, Michael Stiller et autres
Biocompatible materials such as titanium are regularly applied in oral surgery. Titanium‐based implants for the replacement of missing teeth demand a high mechanical precision in order to minimize micro‐bacterial leakage, especially when two‐piece concepts are used. Synchrotron‐based hard x‐ray radiography, unlike conventional …
de, fr (code pays fourni par la source)
Norio Watanabe, T. Sasaya, Y. Imai, So Iwata et autres
An x‐ray microscope with a zone plate was assembled at the synchrotron radiation source of BL3C, Photon Factory. A Foucault knife‐edge was set at the back focal plate of the objective zone plate and phase retrieval was tested by scanning the knife‐edge. …
jp (code pays fourni par la source)
Mareike Brettholle, S.‐C. Gleber, Beate Mekiffer, D. Legnini et autres
A combination of x‐ray microscopy, elemental mapping, and XANES spectroscopy at the K‐absorption edge of sulfur was used to analyze the elemental and particulate composition of an urban soil loaded with building rubble from WWII, exemplarily from Berlin, Germany. This combination of …
us, de (code pays fourni par la source)
Stefan Rehbein, Peter Guttmann, Stephan Werner, Gerd Schneider et autres
The Helmholtz-Zentrum Berlin (HZB) operates a transmission x-ray microscope (TXM) in the soft x-ray photon energy range with an energy resolution up to E/E = 10 4 [1].An approach to achieve ultrahigh spatial resolution with conventional, standard zone plate optics is to …
de (code pays fourni par la source)
W. Li, Jeff Gelb, Yanjing Yang, Yong Guan et autres
3D visualizations of complex structures within various samples have been achieved with high spatial resolution by X‐ray computed nanotomography (nano‐CT). While high spatial resolution generally comes at the expense of field of view (FOV). Here we proposed an approach that stitched several …
cn (code pays fourni par la source)
F. Zhang, J. M. Rodenburg, Ian McNulty, Catherine Eyberger et autres
Lens‐based imaging is able to directly provide an image of objects. The high quality lenses required, however, are not readily available for x‐rays. Coherent diffraction imaging (CDI) bypasses this difficulty by numerically inverting the diffraction process undertaken by an object wave. The …
gb (code pays fourni par la source)
David Paterson, Martin D. de Jonge, Daryl L. Howard, W. F. Lewis et autres
A hard x‐ray micro‐nanoprobe has commenced operation at the Australian Synchrotron providing versatile x‐ray fluorescence microscopy across an incident energy range from 4 to 25 keV. Two x‐ray probes are used to collect μ‐XRF and μ‐XANES for elemental and chemical microanalysis: a …
au, us (code pays fourni par la source)
BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.