Aller au contenu principal
Profil bibliographique

T. Rack

Informations fournies par OpenAlex. Research Africa ne déduit ni nationalité, ni poste, ni coordonnées personnelles.

19Publications signalées
511Citations signalées
1Affiliations récentes

Les institutions déclarées

Les domaines associés

Advanced X-ray Imaging TechniquesAdvanced X-ray and CT ImagingMedical Imaging Techniques and ApplicationsAdvanced Electron Microscopy Techniques and ApplicationsX-ray Spectroscopy and Fluorescence Analysis

Les publications récentes

Accès ouvert 2014 conference-paper OpenAlex

Reflection on multilayer mirrors: beam profile and coherence properties

Alexander Rack, Christian Morawe, Lucia Mancini, Diego Dreossi et autres

The main advantage of Bragg reflection from a multilayer mirror as a monochromator for hard X-rays, is the higher photon flux density because of the larger spectral bandpass compared with crystal lattice reflection. The main disadvantage lies in the strong modulations of …

fr, it, us, de (code pays fourni par la source)

5 citations Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE
2013 article OpenAlex

An In Vitro Pilot Study of Abutment Stability During Loading in New and Fatigue-Loaded Conical Dental Implants Using Synchrotron-Based Radiography

T. Rack, Simon Zabler, Alexander Rack, H. Riesemeier et autres

Tanja Rack, MS/Simon Zabler, PhD/Alexander Rack, PhD/Heinrich Riesemeier, PhD/Katja Nelson, PhD, DDS: Purpose: The implant-abutment connection of a two-piece dental implant exhibits complex micromechanical behavior. A microgap is evident at the implant-abutment interface, even in the virgin state, and its width varies …

de (code pays fourni par la source)

52 citations The International Journal of Oral & Maxillofacial Implants
2012 conference-paper OpenAlex

Study of multilayer-reflected beam profiles and their coherence properties using beamlines ID19 (ESRF) and 32-ID (APS)

Alexander Rack, Lahsen Assoufid, R. Dietsch, Timm Weitkamp et autres

The use of multilayer mirrors is an interesting alternative for reflective X-ray monochromatization with respect to reflection from crystal optics. The increased photon flux density due to the multilayers' larger bandwidth is of crucial importance for, e.g, full-field X-ray imaging applications. Drawbacks …

fr, us, de (code pays fourni par la source)

7 citations AIP conference proceedings
Accès ouvert 2011 conference-paper OpenAlex

Coherent Synchrotron-Based Micro-Imaging Employed for Studies of Micro-Gap Formation in Dental Implants

T. Rack, Simon Zabler, Alexander Rack, Michael Stiller et autres

Biocompatible materials such as titanium are regularly applied in oral surgery. Titanium‐based implants for the replacement of missing teeth demand a high mechanical precision in order to minimize micro‐bacterial leakage, especially when two‐piece concepts are used. Synchrotron‐based hard x‐ray radiography, unlike conventional …

de, fr (code pays fourni par la source)

0 citations AIP conference proceedings
2011 conference-paper OpenAlex

Performance of Multilayer Monochromators for Hard X-Ray Imaging with Coherent Synchrotron Radiation

R. Dietsch, Alexander Rack, Timm Weitkamp, M. Riotte et autres

We present a study in which multilayers of different periodicity (from 2.5 to 5.5 nm), composition (W/Si, Mo/Si, Pd/B4C, Ru/B4C), and numbers of layers have been compared. Particularly, we chose mirrors with similar intrinsic quality (roughness and reflectivity) to study their performance …

de, cz, fr (code pays fourni par la source)

10 citations AIP conference proceedings
2010 article OpenAlex

Quantitative studies on inner interfaces in conical metal joints using hard x-ray inline phase contrast radiography

Simon Zabler, T. Rack, Alexander Rack, Katja Nelson

Quantitative investigation of micrometer and submicrometer gaps between joining metal surfaces is applied to conical plug-socket connections in dental titanium implants. Microgaps of widths well beyond the resolving power of industrial x-ray systems are imaged by synchrotron phase contrast radiography. Furthermore, by …

fr, de (code pays fourni par la source)

12 citations Review of Scientific Instruments
2010 conference-paper OpenAlex

Ex vivo and in vitro synchrotron-based micro-imaging of biocompatible materials applied in dental surgery

Alexander Rack, Michael Stiller, Katja Nelson, Christine Knabe et autres

Biocompatible materials such as porous bioactive calcium phosphate ceramics or titanium are regularly applied in dental surgery: ceramics are used to support the local bone regeneration in a given defect, afterwards titanium implants replace lost teeth. The current gold standard for bone …

fr, de (code pays fourni par la source)

0 citations Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.