Accès ouvert
2022
article
OpenAlex
Andrew S. Taliaferro, Mahmoud A. Fayed, Edem Tsikata, Regina A. de Luna et autres
Abstract Purpose: To determine if inter-eye asymmetry of a three-dimensional neuroretinal rim parameter, the minimum distance band, is useful in differentiating normal from open-angle glaucoma eyes. Materials and Methods: This is a cross-sectional study. Both eyes of 28 normal subjects 33 glaucoma …
us, nl
(code pays fourni par la source)
Accès ouvert
2020
article
OpenAlex
Stephanie H. Choi, Firas Jassim, Edem Tsikata, Ziad Khoueir et autres
Purpose: To compare artifact rates in two-dimensional (2D) versus three-dimensional (3D) retinal nerve fiber layer (RNFL) scans using Spectralis optical coherence tomography (OCT) Methods: Thirteen artifact types in 2D and 3D RNFL scans were identified in 106 glaucomatous eyes and 95 normal …
us, lb, tw, nl
(code pays fourni par la source)
Accès ouvert
2019
article
OpenAlex
Yingna Liu, Firas Jassim, Boy Braaf, Ziad Khoueir et autres
PRéCIS:: The diagnostic capability of peripapillary retinal volume is similar to peripapillary retinal nerve fiber layer thickness for diagnosing glaucoma, but with fewer artifacts. PURPOSE: To compare the diagnostic capability of 3-dimensional peripapillary retinal volume (RV) versus 2-dimensional peripapillary retinal nerve fiber …
us, lb, tw, il, tr, ph, be, nl
(code pays fourni par la source)
Accès ouvert
2019
article
OpenAlex
Ziad Khoueir, Firas Jassim, Boy Braaf, Linda Yi-Chieh Poon et autres
PRECIS: Three-dimensional (3D) spectral domain optical coherence tomography (OCT) volume scans of the optic nerve head (ONH) and the peripapillary area are useful in the management of glaucoma in patients with a type I or II Boston Keratoprosthesis (KPro). PURPOSE: The purpose …
us, lb, tw, nl
(code pays fourni par la source)
Accès ouvert
2018
article
OpenAlex
Alice Chandra Verticchio Vercellin, Firas Jassim, Linda Yi-Chieh Poon, Edem Tsikata et autres
Purpose: To compare the diagnostic capability of three-dimensional (3D) macular parameters against traditional two-dimensional (2D) retinal nerve fiber layer (RNFL) thickness using spectral domain optical coherence tomography. To determine if manual correction and interpolation of B-scans improve the ability of 3D macular …
us, it, tw, il, tr, ph, nl
(code pays fourni par la source)
Accès ouvert
2017
article
OpenAlex
Ziad Khoueir, Firas Jassim, Linda Yi-Chieh Poon, Edem Tsikata et autres
us, tw, il, tr, ph, nl
(code pays fourni par la source)
Accès ouvert
2013
preprint
OpenAlex
Firas Jassim, Fawzi Altaani
Object oriented design is becoming more popular in software development and\nobject oriented design metrics which is an essential part of software\nenvironment. The main goal in this paper is to predict factors of MOOD method\nfor OO using a statistical approach. Therefore, linear regression …