Accès ouvert
2025
article
OpenAlex
S. Romaniuk, Katarzyna Nowakowska‐Langier, Robert Mirowski, M. Kuk et autres
In this research, the structure and properties of multilayered nickel coatings obtained by vacuum-arc deposition (ArcPVD) have been investigated. The influence of Ni layered coatings after being brazed using silver-based brazing solder on vacuum joints has been determined. The Ni coatings are …
pl, ua
(code pays fourni par la source)
Accès ouvert
2025
article
OpenAlex
Katarzyna Nowakowska‐Langier, M. Kuk, R. Kwiatkowski, A. Malinowska et autres
Abstract The article presents the application of a low‐temperature plasma technique accomplished by controlled arc discharges in ultra‐high vacuum deposition of metallic coatings on ceramic substrates. Such metallic coatings are very important in the diagnostic devices within the magnetic confinement fusion facilities, …
pl
(code pays fourni par la source)
Accès ouvert
2022
article
OpenAlex
Grzegorz Witold Strzelecki, Katarzyna Nowakowska‐Langier, K. Mulewska, Maciej Zieliński et autres
pl, se
(code pays fourni par la source)
2020
article
OpenAlex
J. Lorkiewicz, R. Nietubyć, R. Diduszko, J. Sekutowicz et autres
pl, de
(code pays fourni par la source)
2019
article
OpenAlex
Katarzyna Nowakowska‐Langier, Łukasz Skowroński, Rafał Choduń, Sebastian Okrasa et autres
pl
(code pays fourni par la source)
Accès ouvert
2018
conference-paper
OpenAlex
Jarosław Żebrowski, Lech Jakubowski, M. Rabiński, Marek Jan Sadowski et autres
The paper concerns measurements of runaway electrons (REs) which are generated during discharges in tokamaks. The control of REs is an important task in experimental studies within the ITER-physics program. The NCBJ team proposed to study REs by means of Cherenkov-type detectors …
pl, cz, it
(code pays fourni par la source)
2017
article
OpenAlex
M. Rabiński, Lech Jakubowski, Karol Malinowski, Marek Jan Sadowski et autres
Development of a Cherenkov-type diagnostic system to study runaway electrons within the COMPASS tokamak, Rabinski, M., Jakubowski, L., Malinowski, K., Sadowski, M.J., Zebrowski, J., Jakubowski, M.J., Mirowski, R., Weinzettl, V., Ficker, O., Mlynar, J., Panek, R., Paprok, R., Vlainic, M.
pl, cz, be
(code pays fourni par la source)
2015
conference-paper
OpenAlex
M. Rabiński, Lech Jakubowski, Marek Jan Sadowski, Jarosław Żebrowski et autres
The paper presents feasibility and design studies of Cherenkov-type probes, a development of the measuring head construction designed for different tokamak devices, and in particular the acquisition of optical signals to a data storage system. In order to lower the energy threshold …
pl
(code pays fourni par la source)
2015
conference-paper
OpenAlex
J. Lorkiewicz, R. Nietubyć, J. Sekutowicz, Marek Barlak et autres
Results are reported on using evaporation and UHV arc lead deposition to create thin-layer superconducting Pb photocathodes on niobium wall of electron gun. Evaporated photocathodes were prepared and tested for the first time in 2014. A complete XFEL-type photo-injector with an evaporated …
pl, de
(code pays fourni par la source)
2015
article
OpenAlex
Lech Jakubowski, Karol Malinowski, Robert Mirowski, M. Rabiński et autres
Measurements of fast electrons produced in plasma a nd escaping from tokamak-type facilities are of particular interest for diagnostics, because such electrons deliver information about processes occurring inside bulk plasma. A team from the National Centre for Nuclear Research (NCBJ, former IPJ) …
2014
article
OpenAlex
Lech Jakubowski, Marek Jan Sadowski, Jarosław Żebrowski, Karol Malinowski et autres
This paper presents a summary of the most important results of fast electron measurements performed so far within different tokamaks by means of Cherenkov-type detectors. In the ISTTOK tokamak (IPFN, IST, Lisboa, Portugal), two measuring heads were applied, each equipped with four …
Accès ouvert
2014
article
OpenAlex
J. Lorkiewicz, R. Nietubyć, Marek Barlak, Robert Mirowski et autres
A combination of a ultra high vacuum arc deposition system and a recrystallization method was used to optimize the smoothness and thickness of thin-layer lead cathodes for superconducting niobium electron injectors. A non-filtered arc system was chosen to deposit Pb films on …
pl, de, us
(code pays fourni par la source)