2026
book-chapter
OpenAlex
Riccardo Tommasini, R. Pertusio
The dangers of personnel in high voltage stations can be very elevated, so the sharp evaluation of the resistance to ground of human body ( Reb ) is very useful to establish and improve the safety levels and the plan interventions. The …
2025
conference-paper
OpenAlex
A. L. Kritcher, Dave Schlossberg, Chris Young, Riccardo Tommasini et autres
Inertial confinement fusion (ICF) with lasers is a leading approach for generating and confining nuclear fusion, and it is the only method to date that has attained target gain and ignition, as defined by the Lawson criterion, in a controlled laboratory setting. …
us, cn, de
(code pays fourni par la source)
2020
article
OpenAlex
Pietro Colella, Enrico Pons, Cristian Piran, Riccardo Tommasini
Global Earthing Systems (GESs) are defined by International Standards IEC 61936-1 and EN 50522 as an equivalent Earthing System (ES) created by the interconnection of local ESs. Thanks to this interconnection, just a percentage of the total fault current is injected to …
it
(code pays fourni par la source)
2019
article
OpenAlex
Enrico Pons, Pietro Colella, Roberto Rizzoli, Riccardo Tommasini
DC urban light railway systems are used for public transportation in many towns worldwide. In these systems, short-circuit currents are often similar, both in steady-state magnitude and in rate-of-rise, to normal operation currents. In order to properly set the protection relays, to …
it
(code pays fourni par la source)
Accès ouvert
2019
article
OpenAlex
Pietro Colella, Enrico Pons, Riccardo Tommasini, Maria Luisa Di Silvestre et autres
Both Standards EN 50522 and IEEE 81 propose the fall of potential method (FPM) to carry out the measurement of the resistance to earth (RES) of an earthing system (ES). However, in urban areas, the recommended distances between the ES and auxiliary …
it
(code pays fourni par la source)
2018
article
OpenAlex
Fabio Freschi, Massimo Mitolo, Riccardo Tommasini
This article discusses fundamental electrical safety issues, especially protection against electric shock, for those interacting with electric vehicles (EVs). The safety of users may be challenged by the vehicle's increased operating voltages, at different frequencies, possibly making the protection against direct and …
it, us
(code pays fourni par la source)
Accès ouvert
2017
article
OpenAlex
Giuseppe Cafaro, Pietro Colella, Pasquale Montegiglio, Enrico Pons et autres
In urban and industrial areas, a relevant presence of buried metallic objects (e.g., gas and water pipes, etc.) can be detected. Usually, these elements are imagined as widespread meshed metallic grids in a good contact with the soil. In the last years, …
it
(code pays fourni par la source)
2017
article
OpenAlex
Fabio Freschi, Massimo Mitolo, Riccardo Tommasini
Common solids (e.g., flour, sugar, etc.,) can be suspended and transported in air via pneumatic conveying systems. Finely divided solid substances dispersed into a dust cloud (e.g., into a silo) can form a potential explosive atmosphere, if in the right concentration with …
it, us
(code pays fourni par la source)
Accès ouvert
2017
conference-paper
OpenAlex
Enrico Pons, Pietro Colella, Roberto Rizzoli, Riccardo Tommasini
DC urban light railway systems are used as public transportation systems in many towns worldwide. In these systems, short circuit currents are often similar, both in steady state magnitude and in rate-of-rise, to normal operation currents. In order to properly set the …
it
(code pays fourni par la source)
Accès ouvert
2017
conference-paper
OpenAlex
Pietro Colella, Enrico Pons, Riccardo Tommasini, Eleonora Riva Sanseverino et autres
Both EN 50522 and IEEE Std. 81 propose the Fall of Potential Method (FPM) to carry out the measurement of the resistance to earth of an Earthing System (ES). However, in urban areas, the recommended distances between the ES and auxiliary electrodes …
it
(code pays fourni par la source)
Accès ouvert
2017
conference-paper
OpenAlex
Pietro Colella, Enrico Pons, Riccardo Tommasini
Global Earthing Systems (GESs) are defined by international standards IEC 61936-1 and EN 50522 as an equivalent Earthing System (ES) created by the interconnection of local ESs. Thanks to this interconnection, just a percentage of the total fault current is injected to …
it
(code pays fourni par la source)
Accès ouvert
2017
conference-paper
OpenAlex
Alessandro Ciocia, Valeria Cocina, Pietro Colella, Paolo Di Leo et autres
Arrays of photovoltaic (PV) modules, mounted on metallic structures, always create stray capacitances between active conductors and ground. Thus, leakage currents flowing in these ground capacitances are formed. If the number of PV modules array is high, these currents can reach some …
it