An Individual Measurements of Superconductive Undulator Poles
Fedor P. Kazantsev, Nikolay A. Mezentsev, Vitaly A. Shkaruba
ru (code pays fourni par la source)
Informations fournies par OpenAlex. Research Africa ne déduit ni nationalité, ni poste, ni coordonnées personnelles.
Fedor P. Kazantsev, Nikolay A. Mezentsev, Vitaly A. Shkaruba
ru (code pays fourni par la source)
Sergey V. Khrushchev, V. A. Shkaruba, Nikolay A. Mezentsev, Valery M. Tsukanov et autres
Abstract A 40-pole superconducting wiggler with a field of 4.5 T and a period of 48 mm was developed and created at the Budker Institute of Nuclear Physics for the SKIF fourth generation source of synchrotron radiation now under construction. The wiggler …
ru (code pays fourni par la source)
Fedor P. Kazantsev, A.V. Bragin, A. A. Volkov, A. V. Zorin et autres
Abstract The authors consider a way of measuring the magnetic fields of undulators based on wires with a pulsed current. The technique is promising for creating fine-tuning systems for undulators that can work in real time because a single measurement takes only …
ru (code pays fourni par la source)
F. P. Kazantsev, A.V. Bragin, A. Erokhin, Alexander Sedov et autres
Abstract In this article, a method for measuring the magnetic fields of wigglers and undulators based on a wire with a pulsed current as a high-speed alternative to Hall measurements is considered. An experimental setup for measurements is described. Correcting algorithms of …
ru (code pays fourni par la source)
V. A. Shkaruba, A.V. Bragin, Evgeni Gusev, A. Erokhin et autres
Abstract— Superconducting insertion devices (wigglers and undulators) which are created at the Budker Institute of Nuclear Physics (Siberian Branch, Russian Academy of Sciences) will be the main devices for generating of synchrotron radiation at the SKIF synchrotron light facility under construction. The …
ru (code pays fourni par la source)
Sergey V. Khrushchev, Nikolay A. Mezentsev, A. N. Safronov, V. A. Shkaruba et autres
Abstract A superconducting undulator prototype with 12 mm period and 0.7 T magnetic field has been developed at the Budker Institute of Nuclear Physics (Siberian Branch, Russian Academy of Sciences). The vertical beam aperture is 5 mm, while the magnetic gap is …
ru (code pays fourni par la source)
Alexander Sedov, A.V. Bragin, A. A. Volkov, A. Erokhin et autres
Abstract For stations one to three “Fast processes” of the SKIF synchrotron radiation source under construction, an insertion device is required that generates photons with energies up to 70 keV and has a maximum radiation flux at an energy of 35 keV. …
ru (code pays fourni par la source)
Fedor P. Kazantsev, V. A. Shkaruba, P. V. Kanonik, Nikolay A. Mezentsev
In this article a method for measuring the magnetic fields of wigglers and undulators based on a wire with a pulsed current, as a high-speed alternative to Hall measurements is considered. This method is an attractive base for creating a fine-tuning system …
ru (code pays fourni par la source)
A.V. Bragin, A. Erokhin, M.A. Kholopov, A. A. Kremnev et autres
The CBM detector will research compressed baryon matter on the FAIR facility, GSI, Darmstadt. The superconducting dipole magnet of this detector provides vertical magnetic field with field integral ∼ 1 T*m along a beam length of 1 m. The warm bore distance …
ru (code pays fourni par la source)
A.V. Bragin, A. A. Volkov, Vitaly V. Kubarev, Nikolay A. Mezentsev et autres
Abstract The results of testing and performance characteristics of an indirectly cryocooled superconducting solenoid to be used at the tehrahertz (THz) spectroscopy experimental station of the free-electron laser at the Institute of Nuclear Physics are presented. The superconducting solenoid with a winding …
ru (code pays fourni par la source)
A.V. Bragin, A. A. Volkov, Vitaly V. Kubarev, Nikolay A. Mezentsev et autres
The test results and performance characteristics of an indirectly crycooled superconducting solenoid to be used at the THz spectroscopy experimental station of free-electron laser at the Institute of Nuclear Physics, are presented. The superconducting solenoid with a winding diameter of 102 mm …
ru (code pays fourni par la source)
V. A. Shkaruba, A.V. Bragin, A. A. Volkov, A. Erokhin et autres
Abstract The main devices for generating synchrotron radiation at the SKIF synchrotron light facility under construction will be superconducting wigglers and undulators created at the Budker Institute of Nuclear Physics, Siberian Branch, Russian Academy of Sciences. This report presents the rationale for …
ru (code pays fourni par la source)
BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.