Aller au contenu principal
Accès ouvert déclaré 2004 article

Simplified Volumetric Flow Cytometry Allows Feasible and Accurate Determination of Cd4 T Lymphocytes in Immunodeficient Patients Worldwide

52Citations signalées, ce qui n’est pas une note de qualité
6Institutions déclarées
4Pays d’affiliation déclarés

Rattachement africain : de, Cameroun, Burkina Faso, kh. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

The determination of CD4 cells is of crucial clinical importance for patients with AIDS. However, the high costs involved represent limitations for CD4 cell counting in developing countries. In order to provide an affordable technique, we introduced a simplified volumetric counting (SVC) technique without sample manipulations and investigated it in a multicentre study. Blood samples from 434 healthy donors and immunodeficient patients were tested in eight hospital laboratories in Europe, Africa and Asia. CD4 cell counts were compared using in-house flow cytometric methods and the SVC technique. The SVC method was performed on a low-cost flow cytometer (CyFlow SL, Partec, Münster, Germany) after 15 min antibody incubation without pre-analytic manipulations, such as washing or erythrocyte lysing procedures. Linear regression analysis demonstrated a correlation of r=0.942 (Europe), r=0.952 (Africa) and r=0.989 (Asia) between the SVC technique and the in-house methods. Bland Altman plot analysis of all patient data showed a mean bias between the two methods of +26 CD4 cells in favour of the SVC technique (measured range: 6-1905 cells/microl; median CD4 cell count: 388/microl). Three centres used the FACS-count technique (Becton-Dickinson, San José, Calif., USA) as an in-house method dispensing with pre-analytic manipulations. The comparison of SVC and FACS-count method revealed a mean bias of +32 CD4 cells/microl (median CD4 cell count: 349/microl). The accuracy of the SVC was tested on standards with known CD4 cell counts (n=6) and was shown to be 95.2%. The low-cost device and the simplified no-lyse, no-wash test procedure reduces the costs per determination and facilitates the use of flow cytometry in developing countries.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Simplified Volumetric Flow Cytometry Allows Feasible and Accurate Determination of Cd4 T Lymphocytes in Immunodeficient Patients Worldwide
Date Crossref
01/04/2004
Éditeur
SAGE Publications
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

HIV Research and TreatmentCytomegalovirus and herpesvirus researchHIV/AIDS Research and Interventions

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.