Aller au contenu principal
Accès ouvert déclaré 2026 conference-abstract

A256 Automated nnU-net–based segmentation of intracranial aneurysms and cerebral vessels in 3D rotational angiography for endovascular treatment planning

0Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : de. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Background/Introduction Accurate segmentation of intracranial vessels and aneurysms is essential for endovascular treatment planning and device selection. Current segmentation approaches are predominantly based on thresholding techniques, which frequently require manual correction and may yield inaccurate results due to inhomogeneous contrast opacification of the vasculature. These limitations may substantially affect geometric assessment and consequently influence treatment strategy. Recent advances in deep learning, particularly self-configuring nnU-Net frameworks for biomedical image segmentation, have demonstrated robust performance across a broad range of imaging applications. Objective/Purpose To develop and evaluate an nnU-Net–based framework for automated segmentation of intracranial vessels and aneurysms derived from preprocedural 3D rotational angiography (3DRA). Methods/Case Description An nnU-Net model was trained using 42 3D rotational angiography (3DRA) datasets acquired with a biplane flat-panel angiography system (Azurion, Philips Medical Systems, Amsterdam, Netherlands) from patients with intracranial aneurysms treated at our institution. Reference segmentations were generated using a semi-automated workflow combining thresholding and region-growing techniques and were independently validated by two expert raters. Segmentation performance was assessed using the Dice similarity coefficient (DSC), centerline Dice score (CLDSC), relative volume absolute error (RVAE), and average symmetric surface distance (ASSD). Results/Findings Mean segmentation time using the nnU-Net framework was approximately 50 seconds per sample. Vessel segmentation achieved a DSC of 0.89 ± 0.049, a CLDSC of 0.95 ± 0.054, and an RVAE of 0.134 ± 0.087 compared with the reference standard. Aneurysm segmentation achieved a DSC of 0.897 ± 0.054, an ASSD of 0.574 ± 0.202 mm, and an RVAE of 0.13 ± 0.113. Discussion/Conclusions/Learning Points nnU-Net–based segmentation enables fast and accurate automated segmentation of intracranial vessels and aneurysms in 3DRA. This approach may facilitate automated endovascular treatment planning workflows and improve reproducibility in neurointerventional procedures.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
A256 Automated nnU-net–based segmentation of intracranial aneurysms and cerebral vessels in 3D rotational angiography for endovascular treatment planning
Date Crossref
01/09/2026
Éditeur
BMJ Publishing Group Ltd.
Type
proceedings-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Où se fait cette recherche

  • TUM Klinikum pays non établi dans la notice
    Établissement de santé

TUM Klinikum.

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.