Recorded body height and sex differences in lung-protective ventilation among adults with ARDS: an 11-year single-centre cohort study
Rattachement africain : de. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Abstract Background Lung-protective ventilation (LPV) reduces mortality in ARDS, but adherence remains incomplete and women and shorter patients disproportionately receive tidal volumes above predicted-body-weight (PBW)-based targets. The relative associations of recorded sex and body height with this disparity remain uncertain. Methods Retrospective single-centre cohort study (January 2013 to December 2023, RWTH Aachen University Hospital surgical ICU). Adults (≥ 18 years) with Berlin-definition ARDS receiving mechanical ventilation for ≥ 72 h were included. Patient-level adherence to lung-protective targets was described, and repeated-measure PBW-normalised tidal volume and mechanical power were analysed with linear mixed-effects models containing a patient-level random intercept and fixed effects for recorded sex, centred recorded height, age, BMI, SAPS II, SOFA, ARDS aetiology, linear relative ICU day and the lowest same-day PaO₂/FiO₂ ratio. Results Among 798 adults (263 women [33.0%]), unadjusted analyses showed that women received higher tidal volumes per kg PBW than men (median, 7.6 vs. 6.8 mL/kg PBW; p < 0.001), with lower VT adherence (55.3% vs. 76.1%; p < 0.001), higher plateau and driving pressures, and higher PBW-normalised mechanical power. In 527 patients contributing 58,802 observations, the simultaneous adjusted VT model yielded a female-sex coefficient of 0.051 mL/kg PBW (95% CI, −0.273 to 0.376; p = 0.756), whereas recorded height was inversely associated with VT/kg PBW (β per cm, −0.0342; 95% CI, −0.0498 to −0.0185; p < 0.001); the sex-by-height interaction was not supported (p = 0.971). In the corresponding mechanical-power model (410 patients; 44,725 observations), the female-sex coefficient was −0.0158 J·min⁻ 1 ·kg PBW⁻ 1 (95% CI, −0.0512 to 0.0196; p = 0.384). Conclusions Unadjusted analyses showed lower lung-protective ventilation adherence in women. In the simultaneous adjusted model, recorded height, but not recorded sex, was independently associated with VT/kg PBW. Because PBW incorporates both sex and height and recorded height was not validated against a reference measurement, the study does not establish mediation or measurement error as the underlying mechanism. Standardised direct height measurement and PBW-based decision support warrant prospective evaluation.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Recorded body height and sex differences in lung-protective ventilation among adults with ARDS: an 11-year single-centre cohort study
- Date Crossref
- 31/08/2026
- Éditeur
- Springer Science and Business Media LLC
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.