Point‐of‐Care White Blood Cell Differential Testing in Pediatric Inpatients (2 Months–17 Years): How Does HemoScreen Perform?
Rattachement africain : it. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
BACKGROUND: Point-of-care (POC) hematology testing is of growing interest in pediatric practice. We previously evaluated an image-based POC hematology analyzer (HemoScreen, PixCell Medical, Yokneam Illit, Israel) for total white blood cell (WBC), red blood cell, and platelet counts and associated indices in pediatric inpatients. Given the diagnostic importance of WBC differentials, this study aimed to extend the evaluation to five-part differential counts. METHODS: -EDTA samples from pediatric inpatients aged 2 months-17 years. Complete blood counts were obtained with the Sysmex XN-1000 (Sysmex Co., Kobe, Japan) and reanalyzed with HemoScreen. Blood smears were digitized with CellaVision DC-1 (CellaVision AB, Lund, Sweden) and reviewed by cytologists. HemoScreen WBC differential percentages were directly compared with cytologist-reviewed digital microscopy, whereas absolute counts were compared with composite values calculated from microscopy-derived percentages and the Sysmex WBC count. Analytical agreement, diagnostic concordance and flagging performance were assessed. RESULTS: Of 141 samples, 138 were suitable for analysis. Correlations for WBC subsets were strong to excellent (ρ = 0.625-0.977). Mean bias was within or close to EFLM-derived acceptable limits for neutrophils and lymphocytes. Diagnostic agreement was excellent for neutropenia, neutrophilia, and lymphocytopenia, and good for lymphocytosis, monocytosis, and eosinophilia. HemoScreen flagged 31.9% of samples for abnormal cells, with sensitivity 74.1%, specificity 78.4%, positive predictive value 45.5%, negative predictive value 92.6%, and overall efficiency 77.5%. CONCLUSIONS: In pediatric venous samples, HemoScreen showed good analytical and diagnostic performance for the five-part WBC differentials. Its abnormal-cell flagging may support prioritization of morphological review, although its workflow impact requires further evaluation.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Point‐of‐Care White Blood Cell Differential Testing in Pediatric Inpatients (2 Months–17 Years): How Does HemoScreen Perform?
- Date Crossref
- 19/08/2026
- Éditeur
- Wiley
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Marche Polytechnic University pays non établi dans la noticeUniversité ou école supérieure
-
Ospedali Riuniti di Ancona pays non établi dans la noticeÉtablissement de santé
-
University of Padua pays non établi dans la noticeUniversité ou école supérieure
-
SOD Medicina di Laboratorio Azienda Ospedaliero Universitaria delle Marche Ancona Italy pays non établi dans la noticeInstitution
-
Laboratory Medicine Unit University‐Hospital of Padua Padua Italy pays non établi dans la noticeUniversité ou école supérieure
-
Department of Medicine Università degli Studi di Padova Padua Italy pays non établi dans la noticeInstitution
Marche Polytechnic University, Ospedali Riuniti di Ancona et University of Padua, avec 3 autres affiliations.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.