Aller au contenu principal
Accès ouvert déclaré 2026 article

Estimating pediatric lung volumetric parameters via rapid, limited‐slice, free‐breathing thoracic dynamic MRI

0Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: Dynamic, separate lung volume assessment during breathing is critical for evaluating thoracic disorders like scoliosis, thoracic insufficiency syndrome (TIS), and pulmonary diseases, as well as for monitoring treatments. While traditional volumetric assessment relies on static 3D imaging during breath-holds, this is unfeasible for many pediatric patients or those with severe respiratory distress. Free-breathing 4D dynamic MRI (dMRI) is the ideal modality due to its lack of radiation, excellent soft-tissue contrast, and flexible imaging planes. However, its clinical use is hampered by long acquisition times, during which patients struggle to maintain stable, consistent breathing patterns or remain still. Consequently, methods to accelerate dMRI acquisition while maintaining volumetric accuracy are urgently needed to make free-breathing assessments clinically practical. PURPOSE: We present an observational study involving free-breathing short-scan-time dynamic MRI (dMRI) method that can be routinely used for computing dynamic lung volumes accurately. METHODS: (1) Full sampled free-breathing sagittal 2D dMRI scans are gathered from 45 normal children via bSSFP sequence. Sparse dMRI (s-dMRI) scans are simulated from these datasets by optimally subsampling in the spatio-temporal domains via a limited number of selected sagittal locations and time instances. (2) A 4D image is constructed from both scans. Lungs are segmented from 4D image, and their volumes from full and sparse dMRI scans are computed. (3) A regression model is developed to predict full-scan volumes from sparse-scan data on a training set. (4) The accuracy is analyzed on both synthesized sparse dMRI scans from a separate fully-sampled-scan test set and actual s-dMRI scans prospectively acquired from 10 normal children. RESULTS: With 5 slices per lung and 40 time points, the predicted volume showed a ∼2% deviation from the full-scan volume, with a total scan-time of ∼9 min (vs. 49.72 ± 5.01 min for the full scan with 15-22 slices per lung and 80 time points). When the spatial sampling was increased to full number of slices (15-22 per lung) but only 40 time points, these metrics become 0.4%, and 24.86 ± 2.5 min. CONCLUSIONS: s-dMRI is a practical approach for computing dynamic lung volumes that can be used routinely with no radiation concern, especially on patients who cannot tolerate long acquisition times.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Estimating pediatric lung volumetric parameters via rapid, limited‐slice, free‐breathing thoracic dynamic MRI
Date Crossref
01/08/2026
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Où se fait cette recherche

  • University of Pennsylvania pays non établi dans la notice
    Université ou école supérieure
  • Children's Hospital of Philadelphia pays non établi dans la notice
    Organisme public
  • Hospital of the University of Pennsylvania pays non établi dans la notice
    Établissement de santé

University of Pennsylvania, Children's Hospital of Philadelphia et Hospital of the University of Pennsylvania.

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Atomic and Subatomic Physics ResearchScoliosis diagnosis and treatmentRespiratory Support and Mechanisms

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.