Aller au contenu principal
Accès ouvert déclaré 2026 preprint

A Breast Vision Pathology Foundation Model for Real-world Clinical Utility

0Citations signalées, ce qui n’est pas une note de qualité
0Institutions déclarées
0Pays d’affiliation déclarés

Le résumé fourni par la source

Pathology foundation models have shown strong retrospective performance, but whether such systems can support clinically relevant use remains unclear. This challenge is particularly important in breast cancer, where pathological assessment serves as the gold standard for diagnosis and guides treatment planning, surgical decision-making and risk stratification across pre-, intra- and post-operative stages. Here we present \textbf{BRAVE}, a breast-adaptive pathology foundation model developed and evaluated using a total resource of 101,638 breast whole-slide images from 32 sources across Asia, Europe and North America. We assessed BRAVE across 34 tasks in 82 cohorts spanning pre-operative biopsy, intra-operative frozen section and post-operative resection, using an evidence chain comprising retrospective benchmarking, clinically challenging scenarios, workflow-oriented clinical impact simulations, prospective observational validation with the thresholds locked in the retrospective cohorts and crossover pathologist-AI interaction studies. Across these settings, BRAVE supported practical roles in the clinical workflow, including safe exclusion of low-risk cases from routine review, AI-assisted second-review rescue of initially missed positives and prioritization of cases for further assessment. In prospective validation across three centres, BRAVE excluded 76.9% of negative biopsy cases (NPV 0.953) and 70.1% of negative frozen-section cases (NPV 0.973), and triaged 78.8% of post-operative subtyping cases as high-confidence clear-cut cases (NPV 1.000). In reader studies, AI assistance improved balanced accuracy from 88.5% to 95.1% (OR 3.14, P<0.001), with better efficiency, confidence and inter-rater agreement. BRAVE-derived scores also independently predicted disease-free survival (adjusted HR 4.79, P<0.001) and overall survival (adjusted HR 8.14, P<0.001).

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

La source scientifique ouverte est momentanément indisponible.

Les sujets associés

AI in cancer detectionRadiomics and Machine Learning in Medical ImagingBreast Cancer Treatment Studies

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.