Aller au contenu principal
2026 article

Impact of unfavorable aortic anatomy on transcatheter aortic valve replacement outcomes

0Citations signalées, ce qui n’est pas une note de qualité
25Institutions déclarées
9Pays d’affiliation déclarés

Rattachement africain : it, ch, de, fr, us, es, ie, dk, ca. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: Despite device improvements for transcatheter aortic valve replacement (TAVR) and increased operator expertise, unfavorable aortic root anatomy might subtend worse procedural and clinical outcomes. The aim of the study is to assess procedural and clinical outcomes of transfemoral TAVR in patients with and without unfavorable aortic root anatomy and receiving Evolut PRO/PRO+ or SAPIEN 3 Ultra devices in contemporary clinical practice. METHODS: Patients enrolled in the multicenter OPERA-TAVI registry were considered. Patients were compared using propensity score matching according to the presence or absence of unfavorable anatomical characteristics of the aortic root [bicuspid aortic valve (BAV), moderate-to-severe left ventricular outflow tract calcifications, horizontal aorta]. Primary endpoints were Valve Academic Research Consortium (VARC)-3 device success and early safety. The secondary endpoint was a composite of 1-year all-cause death, disabling stroke and heart failure rehospitalization. RESULTS: Among a total of 1815 patients, 629 patients (34.7%) had at least one unfavorable characteristic. After adjustment, 624 matched pairs of patients were compared.VARC-3 device success (85.3% vs. 92.0%, P < 0.001) and early safety (72.9% vs. 79.6%, P = 0.006) were lower in patients with unfavorable characteristics. The secondary composite endpoint was higher in patients with unfavorable anatomical characteristics (Kaplan-Meier estimates 15.3 vs. 12.0%; Plogrank = 0.019). Among patients with unfavorable anatomical characteristics, BAV alone was associated with early safety [odds ratio 2.15, 95% confidence interval 1.04-4.70, P = 0.05]. CONCLUSIONS: Patients undergoing transfemoral TAVR had lower rates of device success and early safety in the presence of unfavorable anatomical characteristics, along with worse 1-year clinical outcomes. However, BAV was associated with higher early safety in this context.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Impact of unfavorable aortic anatomy on transcatheter aortic valve replacement outcomes
Date Crossref
30/01/2026
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac Valve Diseases and TreatmentsAortic Disease and Treatment ApproachesCardiovascular Function and Risk Factors

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.