Abstract DP364: Association of deep learning segmented ischemic core hypodensity on non-contrast CT with endovascular treatment benefit
Rattachement africain : us, ca, au, es. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Background: Endovascular treatment (EVT) is effective for patients with large ischemic cores caused by a large vessel occlusion. The size and severity of hypodense tissue on non-contrast CT (NCCT) in the ischemic core predict poor outcomes despite successful EVT. Automated ASPECTS tools can estimate the size and severity of hypodensity on NCCT, but these estimates do not accurately represent the ischemic core. Deep learning (DL) based segmentation of hypodensity on NCCT may offer improved precision. We compared the associations between (1) ischemic core volume on CTP, (2) manually segmented, or (3) DL segmented hypodensity volumes on NCCT and outcomes after EVT or medical management (MM) in patients with a large ischemic core. Methods: We performed a post-hoc analysis of SELECT2 trial patients. The volume of total hypodense (all segmented voxels) and severely hypodense (segmented voxels with ≤26 HU) tissue was measured on baseline NCCT using an externally validated DL model or manual segmentations (Figure 1). The ischemic core volume was determined using CTP (rCBF<30%). We assessed agreement between DL and manually delineated volumes with the concordance correlation coefficients (CCC). Zou's Modified Poisson regression adjusted for age and baseline NIHSS was used to estimate the association of volume measures with 90-day independent ambulation (modified Rankin Scale ≤3), stratified by MM and EVT arms. Interaction p-values assessed whether volume measures modified EVT benefit. Results: 316 patients were included (154 MM, 162 EVT). Agreement between manual and DL segmented volumes was (CCC: 0.73[95%CI:0.67-0.78]) for total hypodense volume and (CCC: 0.90[95%CI:0.88-0.92]) for severely hypodense volume (Figure 2A-2B). Although manual and DL total hypodense volume on NCCT and ischemic core volume on CTP or MRI were associated with lower proportions of independent ambulation after EVT, we observed no association with EVT benefit (rows 1-3 Table 1). Severely hypodense volumes determined with either DL or manual segmentations were associated with a lower chance of independent ambulation after EVT and were significantly associated with reduced EVT benefit (rows 4-5 Table 1, Figure 2C-D). Conclusion: Severely hypodense volumes on NCCT are comparable between automated deep learning and manual segmentations. Our findings suggest that automated deep learning quantification of severe hypodensity on NCCT can help to identify patients less likely to benefit from EVT.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Abstract DP364: Association of deep learning segmented ischemic core hypodensity on non-contrast CT with endovascular treatment benefit
- Date Crossref
- 01/02/2026
- Éditeur
- Ovid Technologies (Wolters Kluwer Health)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.