Aller au contenu principal
Accès ouvert déclaré 2026 article

Integration of Shear-Wave Elastography and Inertial Motion Sensing for Quantitative Monitoring of Tendon Remodeling After Shockwave Therapy in Greater Trochanteric Pain Syndrome

0Citations signalées, ce qui n’est pas une note de qualité
7Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : it. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Background: Greater trochanteric pain syndrome (GTPS) is associated with structural tendon alterations and functional impairment. Extracorporeal shockwave therapy (ESWT) is a common treatment, but objective monitoring of tendon remodeling and motor recovery remains limited. Objective: This study aimed to integrate shear-wave elastography (SWE) expressed in m/s and wearable inertial measurement unit (IMU) as biosensing tools for the quantitative assessment of tendon elasticity, morphology, and hip motion after ESWT in GTPS. Methods: In a prospective cohort of adults with chronic GTPS, shear wave elastography (SWE) quantified gluteus medius tendon (GMT) elasticity and thickness, while hip abduction range of motion (ROM) was measured using a triaxial inertial measurement unit. Clinical scores on the Visual Analogue Scale (VAS), Harris Hip Score (HHS), Low Extremity Functional Scale (LEFS), and Roles and Maudsley score (RM) were collected at baseline (T0) and at 6 months (T1). Results: Thirty-five patients completed follow-up. Pain and function improved significantly (VAS, HHS, LEFS, RM; all p < 0.05). SWE values of the affected GMT increased, while tendon thickness decreased yet remained greater than on the contralateral side. Hip abduction ROM increased significantly from T0 to T1 (p < 0.05). Correlation analysis showed a negative association between abduction and pain at T1 (r = −0.424; p = 0.011) and, at baseline, between abduction and VAS (r = −0.428; p = 0.010) and RM (r = −0.346; p = 0.042), and a positive association with LEFS (r = 0.366; p = 0.031). SWE correlated negatively with VAS at T1 (r = −0.600; p < 0.05) and positively with HHS at T1 (r = 0.400; p < 0.05). Conclusions: Integrating elastography with inertial sensor-based motion analysis provides complementary, quantitative insights into tendon remodeling and functional recovery after ESWT in GTPS. These findings support combined imaging and wearable motion measures to monitor treatment response over time.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Integration of Shear-Wave Elastography and Inertial Motion Sensing for Quantitative Monitoring of Tendon Remodeling After Shockwave Therapy in Greater Trochanteric Pain Syndrome
Date Crossref
12/01/2026
Éditeur
MDPI AG
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Tendon Structure and TreatmentLower Extremity Biomechanics and PathologiesHip disorders and treatments

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.