Aller au contenu principal
Accès ouvert déclaré 2026 article

453. Shorter Duration of Antimicrobial Therapy is Noninferior for Cardiovascular Implantable Electronic Device Associated Systemic Infections

0Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Abstract Background Cardiovascular implantable electronic device (CIED) associated infection is the most common indication for lead extraction. While the need for complete device removal is well established, this study is the first to examine the impact of antimicrobial duration on clinical outcomes.Figure 1:Overall Survival Post-CIED Lead Extraction Stratified by Duration of Antibiotic Therapy Methods We reviewed all patients who underwent CIED lead extraction at our institution between June 2013 and December 2023. Patients who had extraction for a primary indication of bacteremia or lead-associated vegetation were included. Duration of antibiotics prescribed was stratified by initial decision to treat, ≤ 2 weeks or > 2 weeks post-extraction. Measured outcomes were all-cause mortality at 90 days, rates of recurrence or relapse of bacteremia from the same organism, infectious complications, and post-operative disposition to intensive care unit (ICU). Results Of 747 patients reviewed, 79 cases met inclusion criteria. Baseline characteristics were very similar between cohorts. Median duration of antibiotic therapy was 12.6 and 38.6 days, respectively. Kaplan-Meier survival analysis showed no significant difference in survival (p= 0.438, HR 0.693, 95% CI 0.085-5.652). There was no difference in rates of recurrent bacteremia (7% vs 6%, p=0.952), infectious complications (27% vs 30%, p=0.817), hospital length of stay (mean 9.9 vs 13.3, p=0.360), post-operative ICU disposition (0% vs 17%, p=0.112), and rates of cardiac arrest (7% vs 5%, p=0.577) between patients who were prescribed ≤ 2 weeks of antibiotics versus > 2 weeks of antibiotics, respectively. Relapse or recurrence was seen in 5 patients, all of whom had Staphylococcus aureus (n=3) or Serratia sp. (n=2) and either an LVAD or valve replacement. Conclusion Shorter durations (≤ 2 weeks) of antimicrobial therapy after CEID lead extraction was not associated with increased mortality or higher rate of recurrent bacteremia. Among the few patients that experienced relapse or recurrence in both groups, all were associated with high-risk organisms for secondary seeding of other cardiovascular prostheses. Larger studies are needed to define optimal antibiotic duration and determine risk factors for recurrent bacteremia in this population. Disclosures All Authors: No reported disclosures

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
453. Shorter Duration of Antimicrobial Therapy is Noninferior for Cardiovascular Implantable Electronic Device Associated Systemic Infections
Date Crossref
01/01/2026
Éditeur
Oxford University Press (OUP)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Où se fait cette recherche

  • Baylor College of Medicine pays non établi dans la notice
    Université ou école supérieure

Baylor College of Medicine.

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac pacing and defibrillation studiesMedical Device Sterilization and DisinfectionMechanical Circulatory Support Devices

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.