In vivo assessment of airway wall compliance during inhalation injury response using anatomical optical coherence elastography

0Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Significance: Inhalation injury, a critical complication in patients with severe burns, contributes substantially to morbidity and mortality. Current diagnostic practices suffer from subjectivity and lack quantitative metrics. Enhanced diagnostic accuracy is imperative for improving treatment outcomes. Aim: Our objective was to develop normalized cross-sectional compliance (nCsC) of the airway wall, as measured by anatomical optical coherence tomography (aOCT), to reflect the severity of trachea inhalation injury. Approach: We employed a customized aOCT system that incorporates an intraluminal pressure probe to assess nCsC in vivo in pigs subjected to steam-induced inhalation injuries. Multiple steam intensity levels of injury were induced, and nCsC was measured from the carina to the larynx at time points up to 6 h using aOCT. Histological analysis was performed post-mortem. Results: We revealed that airway wall nCsC decreased initially after injury but exhibited recovery at 4 h. This is supported by ANOVA results showing that nCsC was significantly influenced by time (p=0.002). Linear regression indicated that nCsC was negatively correlated with anatomical position (p=0.047), whereas histological injury grade was positively correlated with position (p=0.015). In other words, nCsC decreased and injury grading increased when closer to the site of steam introduction. Conclusions: Airway wall nCsC is a promising quantitative metric for assessing inhalation injury. Future translation of this aOCT-based technology to humans may potentially enhance clinical management of inhalation injuries.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

La source scientifique ouverte est momentanément indisponible.

Où se fait cette recherche

  • University of North Carolina at Chapel Hill pays non établi dans la notice
    Université ou école supérieure

University of North Carolina at Chapel Hill.

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Optical Coherence Tomography ApplicationsUltrasound Imaging and ElastographyPhotoacoustic and Ultrasonic Imaging

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.