Evaluating force and motion in posterior vitreous detachment manoeuvres using a robotic data acquisition system in cadaveric human eyes
Rattachement africain : ir, ca. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Deep vitrectomy, a complex ophthalmic procedure, demands precise instrument control and remains challenging to master. This study evaluated the ARASH:ASiST robotic system as a platform for real-time, quantitative assessment of deep vitrectomy in a pre-clinical setting using cadaveric human eyes. The system records force and motion data without disrupting the surgical workflow. Cadaveric eyes were prepared under strict safety protocols, and a mannequin head with a customised eye holder was designed, refined through repeated testing, and approved by surgeons to fully imitate real-world conditions. Four surgeons with different levels of experience, defined by their years of practice, performed the “drunk walk” manoeuvre while intraoperative force, positional, and temporal data were captured. Despite the inherent limitations of human cadaveric eyes, the aim was to reproduce the drunk walk method as a precise, predefined trajectory for posterior vitreous detachment induction. In total, 14 surgical trials were recorded: 2 from one expert surgeon (right-handed), 4 from two fellows (right-handed), and 8 from one intermediate surgeon, who performed four procedures with each hand. Quantitative metrics, including Normalised Jerk, Force Range, Peak Force Magnitude, and Force RMS, were used to compare individual performances. Group-level comparisons between expert, fellow, and intermediate surgeons were conducted using ANOVA and Kruskal–Wallis tests. While not statistically significant, likely due to the limited sample size, the analysis of descriptive statistics and effect sizes indicated potential trends in performance metrics across experience levels, highlighting the feasibility of the platform for capturing such variations. During data acquisition, the robotic system’s remote-centre-of-motion was accurately calibrated with laser-based technology, while encoders and force sensors were also precisely calibrated. The system’s real-time graphical interface provided immediate feedback and enabled detailed postoperative analysis. Usability testing confirmed its practicality and non-intrusiveness. Overall, the ARASH:ASiST system demonstrates feasibility as an objective platform for the evaluation of deep vitrectomy based on ex vivo results. These findings support further validation of this prototype in synthetic and clinical environments.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Evaluating force and motion in posterior vitreous detachment manoeuvres using a robotic data acquisition system in cadaveric human eyes
- Date Crossref
- 12/12/2025
- Éditeur
- Springer Science and Business Media LLC
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
K. N. Toosi University of Technology pays non établi dans la noticeUniversité ou école supérieure
-
Farabi Hospital pays non établi dans la noticeÉtablissement de santé
-
Isfahan University of Technology pays non établi dans la noticeUniversité ou école supérieure
-
University of Isfahan Department of Electrical Engineering pays non établi dans la noticeUniversité ou école supérieure
-
University of Alberta Department of Electrical and Computer Engineering and Department of Biomedical Engineering pays non établi dans la noticeUniversité ou école supérieure
-
Faculty of Electrical Engineering Applied Robotics and AI Solutions (ARAS) pays non établi dans la noticeUniversité ou école supérieure
-
Tehran University of Medical Sciences Translational Ophthalmology Research Centre pays non établi dans la noticeUniversité ou école supérieure
K. N. Toosi University of Technology, Farabi Hospital et Isfahan University of Technology, avec 4 autres affiliations.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.