A Novel Method for Optimal Woven EndoBridge Device Sizing by Inscribing a Rectangle in Aneurysm Projections on 2-Dimensional Angiograms
Rattachement africain : jp. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
The Woven EndoBridge device is used for endovascular treatment of wide-neck bifurcation cerebral aneurysms. Conventional sizing methods often result in oversizing and require subsequent resizing. Although recent studies demonstrated the accuracy of volumetric methods for sizing, they are often complex. We aimed to develop a simplified method for estimating the appropriate Woven EndoBridge size using two-dimensional angiographic images by inscribing rectangles in aneurysms modeled as ellipsoids, which we named the Inscribed Rectangle Method. This retrospective, single-center study included 12 patients with wide-neck bifurcation cerebral aneurysms treated with the Woven EndoBridge device between May 2023 and July 2024. Aneurysm projections were approximated as ellipses, with the horizontal and vertical axes corresponding to the aneurysm's mean width and minimum height, respectively. The largest inscribed rectangle dimensions (Drec, Hrec) were calculated. We then developed a predictive formula for Woven EndoBridge sizing based on Drec and Hrec and compared its performance with conventional sizing methods. Adequate perioperative occlusion was achieved in 83% of cases, and no significant procedural complications were observed. Analysis of these cases revealed that the implanted Woven EndoBridge width and height were approximately Drec × 1.5 and Hrec, respectively. The Inscribed Rectangle Method, which uses Drec × 1.5 and Hrec, more closely predicted the implanted Woven EndoBridge size than conventional methods (p < 0.01). The Inscribed Rectangle Method provides a simplified, two-dimensional angiography-based approach for Woven EndoBridge sizing that may reduce the need for device resizing while preserving procedural efficiency.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- A Novel Method for Optimal Woven EndoBridge Device Sizing by Inscribing a Rectangle in Aneurysm Projections on 2-Dimensional Angiograms
- Date Crossref
- 15/01/2026
- Éditeur
- Japan Neurosurgical Society
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Iwate Prefectural Central Hospital Department of Neurosurgery pays non établi dans la noticeÉtablissement de santé
-
Tohoku University Department of Neurosurgery pays non établi dans la noticeUniversité ou école supérieure
-
Nansho Hospital pays non établi dans la noticeÉtablissement de santé
Department of Neurosurgery — Iwate Prefectural Central Hospital, Department of Neurosurgery — Tohoku University et Nansho Hospital.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.