Development of a Prototype AWSM-PET Device for Augmented Whole-Body PET Imaging and Initial Human Study

1Citations signalées, ce qui n’est pas une note de qualité
5Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Augmented whole-body scanning via magnifying PET (AWSM-PET) is a technology that aims to enhance the image resolution and sensitivity of the clinical PET/CT scanner for whole-body imaging. This study presents the system design, performance evaluation, and results from phantoms and initial human imaging studies. Methods: The AWSM-PET system integrates 2 high-resolution detector panels (“outserts”) with a Biograph Vision PET/CT scanner (Siemens Healthineers). Positioned outside the scanner’s axial field of view, each panel consists of 32 detector modules, each containing a 30 × 30 lutetium oxyorthosilicate crystal array (0.97 × 0.97 × 10 mm³ per crystal) at 1.05-mm pitch. These detectors are packaged and read out using the scanner’s detector electronics assembly. Customized firmware and software were developed to establish the additional coincidence detection among the outserts and the scanner. The system acquires data simultaneously during a whole-body scan using continuous bed motion. List-mode–based image reconstruction software has been developed for AWSM-PET system using the continuous-bed-motion protocol. Performance was evaluated through sensitivity measurements, imaging of a mini-resolution phantom containing multiple groups of hot spheres, a National Electrical Manufacturers Association Image Quality (NEMA IQ) phantom study with custom small-diameter tumor inserts, and an initial human study. Results: The outsert detectors achieved an energy resolution of 11% at 511 keV. The coincidence resolving time between the outserts and between outserts and scanner was 183 and 211 ps full width at half maximum, respectively. Sensitivity increased by up to 18.4%, depending on the source location. Mini-resolution phantom images demonstrated higher peak-to-valley ratios for spheres with a diameter of 6 mm or less compared with native scanner images. In the NEMA IQ study, AWSM-PET achieved a higher contrast recovery ratio (CRC) for the smallest spheric lesion (diameter, 4.88 mm) across all CRC metrics (maximum, peak, and mean) but no improvement for larger lesions compared with high-resolution Biograph Vision images. Initial human imaging confirmed the system’s compatibility with clinical workflows, achieving improved resolution in high-count regions, such as the brain. However, increased noise in low-count regions (e.g., abdomen) was observed and requires further improvement. Conclusion: The prototype AWSM-PET system demonstrated enhanced image resolution and sensitivity of a clinical PET/CT scanner without negatively impacting its performance, showing improved CRC and spatial resolution for small lesions in phantom and human imaging.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Development of a Prototype AWSM-PET Device for Augmented Whole-Body PET Imaging and Initial Human Study
Date Crossref
04/12/2025
Éditeur
Society of Nuclear Medicine
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Où se fait cette recherche

  • Washington University in St. Louis Imaging Science Program pays non établi dans la notice
    Université ou école supérieure
  • Siemens Healthcare (United States) pays non établi dans la notice
    Entreprise
  • Mallinckrodt (United States) pays non établi dans la notice
    Entreprise
  • Jewish Hospital pays non établi dans la notice
    Établissement de santé
  • University of Missouri–St. Louis pays non établi dans la notice
    Université ou école supérieure
  • Siemens Healthineers pays non établi dans la notice
    Institution

Imaging Science Program — Washington University in St. Louis, Siemens Healthcare (United States) et Mallinckrodt (United States), avec 3 autres affiliations.

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Medical Imaging Techniques and ApplicationsRadiation Detection and Scintillator TechnologiesAdvanced X-ray and CT Imaging

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.