Correlation of change in V4c implantable Collamer lens vaulting and pupil diameter in different light conditions

0Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : in. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

PURPOSE: To study the change in the vault of phakic Intraocular Lens (IOL) (pIOL) with RT view anterior segment optical coherence tomography (ASOCT) in different light conditions and define its relationship with the change in pupillary diameter. DESIGN: Prospective Observational Study. METHODS: Thirty eyes of 15 myopic subjects were enrolled. The implantable Collamer lens (ICL) vault was measured in three light conditions: room light, scotopic, and photopic conditions. Pupillary diameter was recorded in three light conditions using ASOCT and ImageJ software. The primary outcome measure was the change in ICL vault from baseline (room light) to scotopic and photopic conditions, respectively. RESULTS: The mean age of participants was 22.33 ± 3.1 years. V4c ICL implantation was done for a mean refractive error of -10.08 ± 4.0D. The mean ICL vault in room light, scotopic, and photopic conditions were 568.57 ± 215.83 µm, 567.47 ± 225.11 µm, and 418.4 ± 210.04 µm, respectively. As compared to room light, there was no significant change in the ICL vault in scotopic condition (P = 0.89), but it was significantly decreased in photopic (P < 0.0001) condition. On regression analysis of change in vault in relation to the change in pupillary diameter, it was found that in photopic condition with every 1 mm decrease in pupil diameter as measured with ImageJ and ASOCT, there was a decrease in vault of 59.51 µm and 56.19 µm, respectively. CONCLUSION: ICL vault decreases consistently and significantly in photopic conditions; however, scotopic condition has an inconsistent and lesser effect.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Correlation of change in V4c implantable Collamer lens vaulting and pupil diameter in different light conditions
Date Crossref
24/11/2025
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Corneal surgery and disordersIntraocular Surgery and LensesOphthalmology and Visual Impairment Studies

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.