Aller au contenu principal
2025 conference-abstract

Abstract 4367514: Association of Cardiopulmonary Resuscitation Strategies with Diffuse Optical Measurements of Cerebral Hemodynamics

0Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Introduction: Hemodynamic-directed cardiopulmonary resuscitation (HD-CPR) targets blood pressure (BP) goals during resuscitation and has shown improved outcomes compared to conventional algorithmic CPR. However, the relationship between specific BP targets and cerebral health remains poorly understood. Objective: Evaluate the association of intra- and post-arrest cerebral hemodynamics, assessed using non-invasive optical neuromonitoring, with CPR strategies that include higher and lower target HD-CPR and algorithmic CPR. Hypothesis: Higher target HD-CPR will result in increased crerebral oxygenation (StO 2 ) and relative blood flow (rCBF) and blood volume (rCBV) compared to lower target HD-CPR or algorithmic CPR. Methods: Invasive BP monitoring and non-invasive optical neuromonitoring were performed in a pediatric swine model of asphyxia-associated cardiac arrest. After baseline (5 min) and asphyxia (7 min), ventricular fibrillation was induced. Animals were randomized to 1) high target HD-CPR with a goal systolic BP of 110 and diastolic BP of 45 mmHg (n=15), 2) low target HD-CPR with a goal systolic BP of 80 and diastolic BP of 30 mmHg (n=15), or 3) algorithmic depth-directed CPR (n=15). During HD-CPR, vasopressor administration was titrated to BP goals versus protocolized administration every 4 min in algorithmic CPR. After 15 min of CPR, animals were eligible for defibrillation. Animals achieving return of spontaneous circulation (ROSC) were monitored for 4 hours post-ROSC. A Kruskal Wallis test compared cerebral hemodynamics between groups during baseline, asphyxia (7th min), CPR (15th min), and post-ROSC (10, 60, and 240th min). Since not all subjects achieved HD-CPR goals intra-arrest, a secondary analysis compared subjects where mean BP in the 10-15th min of CPR was at goal. Results: No intra- or post-arrest group differences were observed in StO 2 , rCBV, rCBF, and MAP (p>0.05; Fig. 1). In the secondary analysis of HD-CPR animals that achieved goal BP, StO 2 was higher in the high (n=8) vs. low (n=10) target BP groups (median [IQR]: 36.5 [32.9, 38.9] vs. 27.8 [20.1, 35.2], p=0.03). Discussion: In our primary intention-to-treat analysis, no differences were observed between CPR strategies. However, high BP target HD-CPR that achieved BP goals increased cerebral oxygenation. This reinforces the established association between BP and cerebral oxygenation. Future work is needed to optimize HD-CPR strategies to consistently achieve higher blood pressures.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Abstract 4367514: Association of Cardiopulmonary Resuscitation Strategies with Diffuse Optical Measurements of Cerebral Hemodynamics
Date Crossref
04/11/2025
Éditeur
Ovid Technologies (Wolters Kluwer Health)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Cardiac Arrest and ResuscitationOptical Imaging and Spectroscopy TechniquesTraumatic Brain Injury and Neurovascular Disturbances

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.