Aller au contenu principal
Accès ouvert déclaré 2025 article

NanoArrayPAD−X: Nanoprobe Array and 3D-µPAD for the Simultaneous Detection of Respiratory Pathogens and Biomarkers at the Point of Care

2Citations signalées, ce qui n’est pas une note de qualité
5Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : es. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Microfluidic paper-based analytical devices (µPADs) are ideal for point-of-care diagnostics due to their low cost, compact size, and ease of use. However, current designs have limited multiplexing capabilities, making it difficult to simultaneously detect pathogens and biomarkers in the same sample. In this work, we introduce NanoArrayPAD−X, a novel µPAD design that combines wax-printed microfluidic networks with an array of nanoprobes for the simultaneous detection of multiple targets. This is achieved by distributing the sample through the microfluidic network containing X detection areas. There, targets are captured through physical interactions and recognized by specific antibody-coated nanoprobes released from the nanoprobe array. This generates X dots whose color depends on the concentration of the targets in the sample. A NanoArrayPAD−5 platform capable of detecting five targets was developed to aid in the diagnosis of ventilator-associated pneumonia (VAP). The sensor array could detect Pseudomonas aeruginosa, Klebsiella pneumoniae, Staphylococcus aureus, Escherichia coli, and the inflammatory biomarker myeloperoxidase (MPO) with a total turnaround time of 25 min, which is faster than waiting for an overnight culture and the results of an ELISA. Notably, our prototype successfully detected the targets in 87 bronchial aspirate (BAS) specimens, thus demonstrating the suitability of the platform for analyzing complex samples with sputum-like qualities. These findings establish NanoArrayPAD−X as a promising tool for the rapid, multiplexed screening of respiratory pathogens and biomarkers, with potential for guiding personalized antimicrobial therapy in suspected cases of nosocomial pneumonia.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
NanoArrayPAD−X: Nanoprobe Array and 3D-µPAD for the Simultaneous Detection of Respiratory Pathogens and Biomarkers at the Point of Care
Date Crossref
28/10/2025
Éditeur
MDPI AG
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Biosensors and Analytical DetectionAdvanced Biosensing Techniques and ApplicationsMicrofluidic and Bio-sensing Technologies

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.