Voxel-Wise Quantification and Multi-planar Visualization of Plaque Contrast Enhancement in Intracranial Vessel Wall MRI
Rattachement africain : us, cn. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Background: Contrast enhancement (CE) of intracranial atherosclerotic plaques is a valuable biomarker for identifying culprit plaques in ischemic stroke, but current assessment methods are limited by qualitative approaches and artifact susceptibility. Purpose: To develop and validate a semi-automated method for visualization and quantification of CE intensity and volume, and evaluate its accuracy and scan-rescan reproducibility. Study type: Retrospective. Population: Two patient groups with intracranial atherosclerotic diseases were included: Group A (n=37, 82 plaques) for developing and validating the CE map against expert review, and Group B (n=11, 23 plaques) for assessing scan-rescan reproducibility. Field Strength/Sequence: 3.0 T, 3D time-of-flight gradient echo sequence and T1-weighted fast spin echo sequences, before and after Gadolinium contrast injection. Assessment: A 3D quantitative CE map was developed that incorporated dedicated multicontrast, multi-planar preprocessing, image intensity normalization, adjustment for enhancement artifacts, and derivation of a signal intensity threshold. Statistical Tests: Receiver operating characteristic curve analysis determined the optimal CE threshold. Sensitivity, specificity, and Cohen's kappa assessed agreement between the quantitative CE map and manual review. Spearman's correlation evaluated CE volume quantification. Intraclass correlation coefficient (ICC) and coefficient of variance (CV) assessed reproducibility. Results: The optimal signal intensity threshold for post-contrast maps was 0.4 plus the median plaque wall intensity on pre-contrast maps. The area under the curve for CE detection was 0.91 (95% CI: 0.87-0.94), with sensitivity and specificity of 0.83 and 0.90. CE volume measurements strongly correlated with expert measurements (Spearman's rho=0.82, p<0.001). Enhancement ratio showed high reproducibility (ICC=0.92, 95% CI: 0.82-0.96), and CE detection demonstrated robust agreement (kappa=0.82, 95% CI: 0.55-1). Data Conclusion: The proposed CE map demonstrated good accuracy compared to expert review and high scan-rescan reproducibility, enabling comprehensive assessment of CE presence, intensity, and volume for evaluating plaque vulnerability in intracranial atherosclerotic disease.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Voxel-Wise Quantification and Multi-planar Visualization of Plaque Contrast Enhancement in Intracranial Vessel Wall MRI
- Date Crossref
- 28/10/2025
- Éditeur
- openRxiv
- Type
- posted-content
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
University of Washington Department of Bioengineering pays non établi dans la noticeUniversité ou école supérieure
-
Nanjing Drum Tower Hospital pays non établi dans la noticeÉtablissement de santé
-
Shanghai Jiao Tong University pays non établi dans la noticeUniversité ou école supérieure
-
Renji Hospital pays non établi dans la noticeÉtablissement de santé
-
University of Washington Applied Physics Laboratory pays non établi dans la noticeStructure de recherche
-
University of Utah Department of Radiology and Imaging Science pays non établi dans la noticeUniversité ou école supérieure
-
School of Medicine Department of Radiology pays non établi dans la noticeUniversité ou école supérieure
Department of Bioengineering — University of Washington, Nanjing Drum Tower Hospital et Shanghai Jiao Tong University, avec 4 autres affiliations.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.