Aller au contenu principal
Accès ouvert déclaré 2025 article

Evaluating micro-computed tomography for investigation of the pediatric hyoid-larynx complex

2Citations signalées, ce qui n’est pas une note de qualité
4Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : nl, be. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: Conventional CT imaging has limitations in detecting subtle fractures or soft tissue hemorrhages of the pediatric hyoid-larynx complex due to its largely unossified, cartilaginous structure, creating a diagnostic gap in forensic investigations. OBJECTIVE: To explore the feasibility of micro-computed tomography (micro-CT) and diffusible iodine-based contrast-enhanced computed tomography (diceCT) as high-resolution imaging techniques for detailed forensic and developmental assessment of the pediatric hyoid-larynx complex. MATERIALS AND METHODS: Five pediatric hyoid-larynx complex samples were obtained during forensic autopsies. Specimens were excised, fixed in formaldehyde, and scanned using micro-CT. Subsequently, samples were stained with buffered Lugol's solution and rescanned for diceCT. Imaging was performed with voxel sizes between 12-35 µm. Scans were assessed by a trained analyst and two experienced forensic (pediatric) radiologists. RESULTS: All five samples were successfully imaged using micro-CT and diceCT. Ossification increased with age: the youngest sample showed minimal ossification, while the oldest showed ossification of the hyoid lesser horn and thyroid cartilage. Anatomical variants included bilateral triticeal cartilages and ossified stylohyoid ligament fragments. DiceCT enabled detailed soft tissue visualization and revealed hyperdense bundles and ossification centers within the thyroid cartilage. Staining was complete in smaller samples but limited in the largest. No traumatic injuries were detected on imaging or autopsy. CONCLUSION: Micro-CT and diceCT offer high-resolution visualization of both ossified and soft tissue structures in the pediatric hyoid-larynx complex. These methods overcome limitations of conventional CT, demonstrating strong potential to enhance forensic evaluation of pediatric neck trauma.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Evaluating micro-computed tomography for investigation of the pediatric hyoid-larynx complex
Date Crossref
14/08/2025
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Restraint-Related DeathsTrauma Management and DiagnosisOropharyngeal Anatomy and Pathologies

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.