Tissue-specific and whole-body insulin sensitivity by integrated imaging and hyperinsulinemic euglycemic clamp: A repeatability study in people with T2DM and overweight/obesity

1Citations signalées, ce qui n’est pas une note de qualité
4Institutions déclarées
2Pays d’affiliation déclarés

Rattachement africain : se, us. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Assessment of glucose uptake by PET imaging under hyperinsulinemic euglycemic clamp (HEC) is an insightful tool for quantification of insulin resistance, a hallmark of diabetes and an area of interest in drug development. To enable the use of the method in metabolic trials, the repeatability of dynamic whole-body PET/MRI assessments of the tissue-specific glucose uptake and the total body glucose utilisation were investigated. The study included participants with type 2 diabetes mellitus (T2DM) and overweight/obesity, for two repeated examinations in standardised conditions. All participants signed informed consent, and the study plan was approved by the Swedish Ethical Review Authority (#2020-04140). After an overnight fast, HEC was established and a series of [ 18 F]FDG-PET/MRI scans were performed. Total body glucose utilisation (M-value) was calculated for the duration of the scan and the tissue-specific metabolic rates of glucose uptake (MRGlu) were calculated using Patlak model. The repeatability was assessed by calculating the intraclass correlation coefficient (ICC). Repeatability was assessed in per protocol set of 12 participants (PPS, defined by a consistent HEC) and in full analysis set (FAS n = 16). The measured M-values and tissue MRGlu demonstrated varying levels of insulin resistance. M-value ICC was 0.95 (95% CI 0.86–0.99) for PPS, indicating excellent repeatability. Tissue-specific MRGlu repeatability was excellent for skeletal muscle (ICC 0.94), and good to at least fair for SAT, VAT, myocardium, and brain. The FAS had lower, but at least fair repeatability, emphasising the importance of standardisation in metabolic assessments. Dynamic [ 18 F]FDG-PET/MRI provides quantitative information on tissue-specific insulin sensitivity during hyperinsulinemic euglycemic clamp with a reliability comparable to total body glucose utilisation assessment. The method has potential to add value in monitoring and evaluating T2DM treatment effects on glucose uptake and insulin resistance in interventional trials.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Tissue-specific and whole-body insulin sensitivity by integrated imaging and hyperinsulinemic euglycemic clamp: A repeatability study in people with T2DM and overweight/obesity
Date Crossref
07/08/2025
Éditeur
Springer Science and Business Media LLC
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Advanced MRI Techniques and ApplicationsMetabolism, Diabetes, and CancerMedical Imaging Techniques and Applications

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.