Cardiac output during flow-titrated high-flow nasal cannula support in a neonatal porcine model
Rattachement africain : us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Background Neonates are more susceptible to acute respiratory failure than older children. It is unknown to what extent high-flow nasal cannula (HFNC) alters intrathoracic pressure (ITP), potentially decreasing cardiac output (CO) due to cardiopulmonary interactions. This study evaluated the impact of flow titration on tracheal pressure (a surrogate for ITP) and CO via HFNC in an established porcine model of neonatal respiratory failure. Unlike prior research, this study examines both ITP and CO demonstrating that although the ITP increased with higher HFNC flows, CO did not decrease. Methods Twenty-three neonatal Landrace-Yorkshire pigs (2–4 kg) were anesthetized, and monitoring lines were placed. Baseline vital signs, CO, mean intratracheal pressure (Ptr), and PaO 2 were measured. CO was assessed via computerized COstatus cardiac system. Lung injury was induced using oleic acid (0.08 mL/kg), resulting in ≤50% reduction in preinjury PaO 2 on 1 L/min oxygen. After injury, in random order, pigs received HFNC flows of 1, 2, and 3 L/kg/min at 100% FiO 2 for 30 min each. Measurements were repeated, and data were analyzed via mixed-effects repeated measures ANOVA. Results After OA injury, PaO 2 significantly decreased (414 to 125 mmHg; p < 0.001). Mean Ptr and PaO 2 increased significantly ( p < .001) with increasing HFNC flow rates. CO showed no significant changes; thus, no correlation between CO with Ptr and/or HFNC flow levels was demonstrated. Conclusions In neonatal respiratory distress, higher HFNC flows improved oxygenation without negatively impacting CO in this neonatal porcine lung injury model, despite increasing intra-thoracic pressure (1–3 L/min/kg).
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Cardiac output during flow-titrated high-flow nasal cannula support in a neonatal porcine model
- Date Crossref
- 06/08/2025
- Éditeur
- SAGE Publications
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Thomas Jefferson University pays non établi dans la noticeUniversité ou école supérieure
-
Nemours Children's Health System pays non établi dans la noticeÉtablissement de santé
-
DuPont (United States) pays non établi dans la noticeEntreprise
-
University of Delaware pays non établi dans la noticeUniversité ou école supérieure
-
Temple University pays non établi dans la noticeUniversité ou école supérieure
-
Nemours Biomedical Research pays non établi dans la noticeInstitution
Thomas Jefferson University, Nemours Children's Health System et DuPont (United States), avec 3 autres affiliations.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.