Aller au contenu principal
Accès ouvert déclaré 2025 article

Corneal Topography Parameters and Tear Film Break-up Characteristics in Keratoconus Patients

0Citations signalées, ce qui n’est pas une note de qualité
1Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : cn. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Aims/Background Previous studies have found that keratoconus (KC) patients are highly susceptible to dry eye disease (DED); however, the specific relationship between KC and DED has not been thoroughly investigated. This study aims to investigate the corneal topography parameters and tear film (TF) break-up characteristics in KC patients with and without DED. Methods This cross-sectional, single-masked study consisted of 44 KC patients (44 eyes; KC group) and 31 normal individuals (31 eyes; control group). All the participants were recruited from the Department of Ophthalmology and Visual Science, Eye & ENT Hospital, Shanghai Medical College, Fudan University (Shanghai, China) from February 2018 to January 2023. They underwent a routine ophthalmic examination, ocular surface disease index questionnaire, corneal fluorescein staining, and Schirmer I test. Additionally, the participants were examined using the Oculus Keratograph® (OCULUS Inc., Arlington, TX, USA) to determine their corneal topography, noninvasive TF break-up time, and TF break-up point. The KC patients were further divided into KC-DED and KC-non-DED subgroups to analyze the impact of KC on TF characteristics and the incidence of DED. Finally, the relationship between the TF break-up point and the maximum cornea curvature quadrant was investigated. Results In the KC group, 21 patients (21 eyes; 47.72%) were diagnosed with DED. The KC-DED and KC-non-DED subgroups exhibited significantly different maximum keratometry (Kmax, p = 0.021), index of surface variance (p = 0.048), and index of height decentration (p = 0.011) values. The logistic model showed a strong correlation between KC-DED incidence and Kmax value (odds ratio = 1.169, 95% confidence interval: 1.020–1.340, p = 0.025). Moreover, the occurrence of DED increased from 36.67% to 71.43% when the Kmax was >52.00 D (χ 2 = 4.623, p = 0.031). Furthermore, TF was more prone to break-up in the maximum corneal curvature quadrant in the KC group than in the control group (p < 0.001). Conclusion TF should be closely monitored in KC patients, as they are highly prone to DED incidence (Kmax >52.00 D) and experience initial TF break-up in the maximum corneal curvature quadrant.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Corneal Topography Parameters and Tear Film Break-up Characteristics in Keratoconus Patients
Date Crossref
25/07/2025
Éditeur
IMR Press
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Où se fait cette recherche

  • Eye & ENT Hospital of Fudan University pays non établi dans la notice
    Établissement de santé
  • Shanghai Medical College Department of Facial Plastic and Reconstructive Surgery pays non établi dans la notice
    Université ou école supérieure

Eye & ENT Hospital of Fudan University et Department of Facial Plastic and Reconstructive Surgery — Shanghai Medical College.

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Ocular Surface and Contact LensCorneal surgery and disordersGlaucoma and retinal disorders

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.