Early improvement on cardiac function and dyssynchrony after physiological upgrading in pacing-induced cardiomyopathy
Rattachement africain : es. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Abstract Background Interventricular dyssynchrony derived from the classic non-physiological stimulation (n-PS) of the right ventricle (RV) is a known cause of left ventricular dysfunction (LVDys). Methods This was a retrospective descriptive single-center study. We analyzed patients who develop LVDys with n-PS, and the results after upgrading to conduction system pacing (CSP). UHF-ECG was performed pre and post implantation of the last patients included. ECG recordings in 16 frequency bands (150-1000Hz) were used to create maps of ventricular depolarization. The maximum time difference between the centers of mass of the complex UHF QRS of leads V1 to V6 (DYS-e 16) and V1 to V8 (DYS-e 18) defined ventricular dyssynchrony. Data were expressed as mean +- standard deviation. Results 27 patients were up-graded to CSP from January/2022 to January/2024 after developing LVDys. Permanent His Bundle pacing (p-HBP) was achieved in 63% (n=17); in the other ten patients left bundle branch area pacing (LBBAp) was performed. The average baseline LVEF improved from 34,5% (27-42) to 47,6% (38.2-57), p<0.001. Telediastolic left ventricle diameter as well as QRS width also decreased. Thresholds remained stable at 6-month follow up. Last eight patients included were studied in terms of ventricular synchrony parameters by UHF-ECG (VDI Technologies), both HBP and the LBBAp achieved significant improvement with respect to baseline parameters. Conclusions LVEF improved in patients with previous n-PS induced cardiomyopathy after upgrading to CSP. LVDys due to dyssynchronopathy is frequent and probably under-diagnosed. UHF-ECG provides useful new information about ventricular activation and will likely improve patient selection for CRT.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Early improvement on cardiac function and dyssynchrony after physiological upgrading in pacing-induced cardiomyopathy
- Date Crossref
- 01/05/2025
- Éditeur
- Oxford University Press (OUP)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Hospital Juan Ramón Jiménez pays non établi dans la noticeÉtablissement de santé
-
Juan Ramon Jimenez University Hospital pays non établi dans la noticeUniversité ou école supérieure
Hospital Juan Ramón Jiménez et Juan Ramon Jimenez University Hospital.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.