Changing Antiarrhythmic Drug Regimen in Patients with Amiodarone and Ablation Refractory Ventricular Tachyarrhythmias Is Associated with Increased Implantable Cardioverter Defibrillator Shocks—A Retrospective Analysis from a Large Tertiary Center
Rattachement africain : de. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Background and Objective: Implantable Cardioverter Defibrillators (ICDs) are crucial in treating ventricular tachyarrhythmias (VTs) and preventing sudden cardiac death. However, ICD shocks are linked to higher mortality and a lower quality of life. Many patients suffer from recurrent VTs despite concomitant antiarrhythmic drug (AAD) therapy with amiodarone, and it is unclear if changing the AAD while on chronic amiodarone therapy is beneficial. Hence, we investigated the impact of changing the AAD on the incidence of appropriate ICD shocks in patients on chronic amiodarone, impaired LV function, and at least one previous VT ablation. Methods and Results: We retrospectively analyzed 131 ICD patients (LVEF < 40%) from a single-center registry. All were on chronic amiodarone and had undergone VT ablation. The mean age was 66.0 ± 12.8 years; 82.4% were male; and the follow-up period averaged 5.8 ± 0.6 years. Ischemic cardiomyopathy was present in 52.7% of patients. AAD therapy was changed in 49 patients (37.4%), primarily due to inefficacy (40.8%), intolerance (16.3%), or other reasons (42.9%). Of those, 8 received flecainide (≥200 mg) and 41 sotalol (≥240 mg); 82 (62.6%) continued amiodarone. VT re-ablation was performed in 23.7%. During follow-up, 11 patients (8.4%) died and 18 (13.7%) received appropriate ICD shocks—17 with changed AAD vs. 1 with continued amiodarone (p ≤ 0.01). A multivariate regression showed that switching from amiodarone to flecainide or sotalol was significantly associated with increased ICD shock risk (OR 34.9; 95% CI 4.3–283.8; p < 0.01). Conclusions: In patients on chronic amiodarone with severely impaired LV function and at least one previous VT ablation, changing AAD therapy to flecainide or sotalol is associated with an increased incidence of appropriate ICD shocks.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Changing Antiarrhythmic Drug Regimen in Patients with Amiodarone and Ablation Refractory Ventricular Tachyarrhythmias Is Associated with Increased Implantable Cardioverter Defibrillator Shocks—A Retrospective Analysis from a Large Tertiary Center
- Date Crossref
- 22/04/2025
- Éditeur
- MDPI AG
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
University Hospital Münster Department for Cardiology II: Electrophysiology pays non établi dans la noticeÉtablissement de santé
Department for Cardiology II: Electrophysiology — University Hospital Münster.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.