Abstract Background and purpose: Adaptive radiotherapy (ART) is commonly used to mitigate effects of anatomical change during head and neck (H&N) radiotherapy. The process of identifying patients for ART can be subjective and resource-intensive. This feasibility project aims to design and validate a pipeline to automate the process and use it to assess the current clinical pathway for H&N treatments. Methods: The pipeline analysed patients’ on-set cone-beam CT (CBCT) scans to identify inter-fractional anatomical changes. CBCTs were converted into synthetic CTs, contours were automatically generated, and the original plan was recomputed. Each synthetic CT was evaluated against a set of dosimetric goals, with failed goals causing an ART recommendation. To validate pipeline performance, a ‘gold standard’ was synthesised by recomputing patients’ original plans on a rescan-CT acquired during treatment and identifying failed clinical goals. The pipeline sensitivity and specificity compared to this ‘gold standard’ were calculated for 12 ART patients. The pipeline was then run on a cohort of 12 ART and 14 non-ART patients, and its sensitivity and specificity were instead calculated against the clinical decision made. Results: The pipeline showed good agreement with the synthesised ‘gold standard’ with an optimum sensitivity of 0·83 and specificity of 0·67. When run over a cohort containing both ART and non-ART patients and assessed against the subjective clinical decision made, the pipeline showed no predictive power (sensitivity: 0·58, specificity: 0·47). Conclusions: Good agreement with the ‘gold standard’ gives confidence in pipeline performance and disagreement with clinical decisions implies implementation could help standardise the current clinical pathway.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- An automated cone-beam CT dosimetric assessment pipeline for adaptive head and neck radiotherapy
- Date Crossref
- 01/01/2025
- Éditeur
- Cambridge University Press (CUP)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Leeds Teaching Hospitals NHS Trust pays non établi dans la noticeÉtablissement de santé
-
RaySearch Laboratories (Sweden) pays non établi dans la noticeEntreprise
-
University of Leeds pays non établi dans la noticeUniversité ou école supérieure
Leeds Teaching Hospitals NHS Trust, RaySearch Laboratories (Sweden) et University of Leeds.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.