Mapping nano- and microporosity in ductile shear zones with X-ray ptychography
Rattachement africain : au, ch. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Petrological and geochemical evidence demonstrates that mylonitic ductile shear zones transport significant amounts of fluids through the lithosphere. Because of the lack of percolating pore networks in exhumed mylonitic rocks, it has been hypothesised that most of the fluid pathways in ductile shear zones consist of transient pores with micro- to nanoscale aperture. These transient pores typically include grain boundaries, creep cavities, and pores due to mineral reactions, all of which open and close cyclically during plastic deformation. However, it is not known how much each of these features contributes to crustal fluid flow. Moreover, nano-scale pores are notoriously difficult to map with non-destructive imaging methods. These are the key problems addressed by this research.We recently used X-ray ptychography to image midcrustal quartzo-feldspathic mylonites at the X-ray Fluorescence Microprobe beamline of the Australian Synchrotron. This transmission small-angle scattering method maps X-ray phase contrast non-destructively with nanometre resolution. In addition, high-resolution trace-element maps are acquired coevally with X-ray Fluorescence Microscopy (XFM). We systematically sampled transects from mylonite to ultramylonite to capture the strain-time evolution of nano- and microvoids and to study how transient porosity and trace-element composition change with deformation intensity, composition, grain size, and deformation mechanism. This dataset will provide novel insights into mass transfer in ductile shear zones.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Mapping nano- and microporosity in ductile shear zones with X-ray ptychography
- Date Crossref
- 18/03/2025
- Éditeur
- Copernicus GmbH
- Type
- posted-content
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Queensland University of Technology pays non établi dans la noticeUniversité ou école supérieure
-
Australian Nuclear Science and Technology Organisation pays non établi dans la noticeOrganisme public
-
Australian Synchrotron pays non établi dans la noticeStructure de recherche
-
University of Bern pays non établi dans la noticeUniversité ou école supérieure
Queensland University of Technology, Australian Nuclear Science and Technology Organisation et Australian Synchrotron, avec 1 autre affiliation.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.