Association of Diabetes with Heart Rate Variability during Hemodialysis
Rattachement africain : us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Key Points Patients with diabetes on hemodialysis had 18% lower SD of the normal-to-normal R-R interval, a proxy for lower heart rate variability. The association of diabetes with intradialytic hypotension was not mediated by SD of the normal-to-normal R-R interval. Targeted therapies to mitigate autonomic neuropathy in patients with diabetes on hemodialysis warrant further investigation. Background Autonomic dysfunction is common among patients with diabetes receiving hemodialysis. We wished to explore the association of diabetes with heart rate variability (HRV; a surrogate of autonomic dysfunction) and whether HRV mediates the association of diabetes with intradialytic hypotension (IDH). Methods In this secondary analysis of the Frequent Hemodialysis Network Daily Trial, we performed the following: ( 1 ) random effects linear regression to estimate the association of diabetes with log-transformed low-frequency (LF) power (proxy of sympathetic activity), high-frequency (HF) power (proxy of parasympathetic activity), ratio of LF/HF (proxy for sympathovagal balance), and SD of the normal-to-normal R-R interval (SDNN, measured at baseline and 12 months) and ( 2 ) linear regression to explore the association of diabetes with changes in HRV parameters over 12 months. Models were adjusted for age, sex, designated race, height, access type, hemodialysis vintage, history of heart failure, prehemodialysis systolic BP, heart rate, ultrafiltration rate, hemoglobin, serum albumin, β -blocker use, calcium channel blocker use, diuretic use, left ventricular mass, and randomized treatment assignment. Results Of the 198 patients without baseline atrial fibrillation, 82 (41%) had self-reported diabetes. In adjusted random effects models, diabetes (versus no diabetes) was associated with lower SDNN −18% (95% confidence interval [CI], −27 to −9) on a per session basis. The presence of diabetes was not associated with differences in LF 7% (95% CI, −20 to 43), HF 10% (95% CI, −10 to 33), or LF/HF −4% (95% CI, −19 to 14). Diabetes (versus no diabetes) was not associated with a change from baseline to 12 months in any HRV parameter. SDNN did not attenuate the observed association of diabetes with IDH. Conclusions Among participants in the Frequent Hemodialysis Network Daily Trial, diabetes (versus no diabetes) was associated with 18% lower SDNN. The association of diabetes with IDH did not seem to be mediated by SDNN. The reasons for higher rates of IDH in patients with diabetes remain elusive. Clinical Trial registry name and registration number: NCT00264758.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Association of Diabetes with Heart Rate Variability during Hemodialysis
- Date Crossref
- 13/03/2025
- Éditeur
- Ovid Technologies (Wolters Kluwer Health)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
Brigham and Women's Hospital pays non établi dans la noticeÉtablissement de santé
-
Harvard University pays non établi dans la noticeUniversité ou école supérieure
-
Stanford University Departments of Medicine pays non établi dans la noticeUniversité ou école supérieure
-
Harvard Medical School pays non établi dans la noticeInstitution
Brigham and Women's Hospital, Harvard University et Departments of Medicine — Stanford University, avec 1 autre affiliation.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.