Enhancing Kidney Quality Assessment: Power Doppler During Normothermic Machine Perfusion
Rattachement africain : nl, de, us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
ABSTRACT Objectives Marginal donor kidneys are increasingly used for transplantation to overcome organ shortage. This study aims to investigate the additional value of Power Doppler (PD) imaging in kidney quality assessment during normothermic machine perfusion (NMP). Methods Porcine kidneys ( n = 22) retrieved from a local slaughterhouse underwent 2 h of NMP. Based on creatinine clearance (CrCl) and oxygen consumption (VO 2 ) at 120 min, kidneys were classified into Group 1 ( n = 7, CrCl > 1 mL/min/100 g and VO 2 > 2.6 mL/min/100 g) and Group 2 ( n = 15, CrCl ≤ 1 mL/min/100 g and/or VO 2 ≤ 2.6 mL/min/100 g). PD imaging was performed at 30, 60, and 120 min, and PD metrics, including vascularization index (VI), flow index (FI), and vascularization flow index (VFI) were calculated. Renal blood flow (RBF), CrCl, and VO 2 were measured at the same time points during NMP. The metrics were compared utilizing correlation analysis. Results FI and VFI moderately correlated with CrCl ( r = 0.537, p < 0.0001; r = 0.536, p < 0.0001, respectively), while VI strongly correlated with VO 2 ( r = 0.839, p < 0.0001). At 120 min, PD metrics demonstrated the highest diagnostic accuracy for distinguishing between the two groups, with an area under the curve (AUC) of 0.943 for VI, 0.924 for FI, and 0.943 for VFI. Cutoff values of 17% for VI, 50 a.u. for FI, and 9 a.u. for VFI provided 100% specificity and 73% sensitivity in identifying kidneys in Group 2, with an overall diagnostic accuracy of 82%. Baseline kidney biopsies showed moderate acute tubular necrosis in both groups, with no significant differences. Conclusions PD metrics strongly correlate with renal viability and effectively differentiate kidneys with higher and lower functionality during NMP. PD imaging can be a valuable alternative to RBF during NMP for kidney quality assessment.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Enhancing Kidney Quality Assessment: Power Doppler During Normothermic Machine Perfusion
- Date Crossref
- 12/03/2025
- Éditeur
- Wiley
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.