Aller au contenu principal
Accès ouvert déclaré 2025 article

First Dimension Trap‐and‐Elute Combined with Second Dimension Reversed‐Phase Liquid Chromatography Separation Using a Two‐Dimensional‐Liquid Chromatography‐Tandem Mass Spectrometry System for Sensitive Quantification of Human Insulin and Six Insulin Analogs in Plasma: Improved Chromatographic Resolution and Stability Testing

4Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : cz. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

Multidimensional chromatography coupled to tandem mass spectrometry (MS/MS), including simple sample preparation with protein precipitation, anion conversion with ammonium hydroxide, and solid-phase extraction using mixed-mode anion exchange in a 96-well plate format, has been validated for rapid simultaneous analysis of human insulin and its six analogs (lispro, glulisine, glargine, degludec, detemir, and aspart) in human plasma. This method is critical for clinical diagnostics, forensic investigations, and anti-doping efforts due to the widespread use of these substances. In the present study, improved chromatographic resolution was achieved using a first-dimension trap-and-elute configuration with an XBridge C18 (2.1 × 20 mm, 3.5 µm) trap column combined with second dimension separation on a Cortecs Ultra-High-Performance Liquid Chromatography (UHPLC) C18+ (2.1 × 100 mm, 1.6 µm) analytical column implemented within a two-dimensional-LC-MS/MS system. The total chromatographic run time was 11 min. This setup increases both the resolution and sensitivity of the method. A mobile phase consisting of 0.8% formic acid (FA) in water and 0.7% FA in acetonitrile was used for gradient elution. Bovine insulin was used as the internal standard. MS detection was performed in positive electrospray ionization mode, and the ion suppression due to matrix effects was evaluated. Validation criteria included linearity, precision, accuracy, recovery, lower limit of quantitation, matrix effect, and stability tests with and without protease inhibitor cocktail under different conditions (short-term stability, long-term stability, and freeze-thaw stability). The concentration range for all insulins was 50-15 000 pg/mL, with limits of quantification below the therapeutic reference range for all analytes. Intra-run precision ranged from 1.1% to 5.7%, inter-run precision from 0.7% to 5.9%, and overall recovery from 96.9% to 114.3%. The validated method has been implemented successfully by the Department of Forensic Medicine at our hospital for the investigation of unexplained deaths.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
First Dimension Trap‐and‐Elute Combined with Second Dimension Reversed‐Phase Liquid Chromatography Separation Using a Two‐Dimensional‐Liquid Chromatography‐Tandem Mass Spectrometry System for Sensitive Quantification of Human Insulin and Six Insulin Analogs in Plasma: Improved Chromatographic Resolution and Stability Testing
Date Crossref
01/02/2025
Éditeur
Wiley
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Où se fait cette recherche

  • University of Ostrava pays non établi dans la notice
    Université ou école supérieure
  • University Hospital Ostrava Department of Clinical Pharmacology pays non établi dans la notice
    Établissement de santé
  • Masaryk University pays non établi dans la notice
    Université ou école supérieure
  • Faculty of Medicine Department of Clinical Pharmacology pays non établi dans la notice
    Université ou école supérieure

University of Ostrava, Department of Clinical Pharmacology — University Hospital Ostrava et Masaryk University, avec 1 autre affiliation.

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Analytical Chemistry and ChromatographyMetabolomics and Mass Spectrometry StudiesAlcohol Consumption and Health Effects

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.