Long‐Term Bioprosthetic Valve Durability After Transcatheter Aortic Valve Replacement With Supra‐Annular Self‐Expanding Versus Intra‐Annular Balloon‐Expandable Valves in Patients With a Small Aortic Annulus
Rattachement africain : jp. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
BACKGROUND: The long-term valve durability of supra-annular self-expanding valves (SEV) and intra-annular balloon-expandable valves (BEV) in patients with small aortic annuli remains unexplored. AIMS: This study aimed to determine the long-term bioprosthetic valve durability with SEV versus BEV in patients with small aortic annuli. METHODS: or less who underwent transcatheter aortic valve replacement using SEV and BEV between October 2009 and December 2022. Based on the Valve Academic Research Consortium's three definitions, the endpoints were hemodynamic structural valve deterioration (SVD) and bioprosthetic valve failure (BVF). Inverse probability of treatment weighting (IPTW) was used to compare between the two groups and adjust for baseline characteristics. The Fine-Gray subdistribution hazard model accounted for the competing risk of death. RESULTS: In total, 565 patients (204 treated with SEV and 361 treated with BEV) were included. The median follow-up duration was 3.6 years [2.0 years, 5.7 years], and the maximum was 12.3 years. Hemodynamic SVD and BVF were less frequently identified in the SEV group than in the BEV group (1.1% vs. 9.1% within 5 years, 0.7% vs. 8.1% within 5 years, respectively). On the IPTW adjusted Fine-Gray subdistribution hazard model analysis, hemodynamic SVD was less frequent in SEV compared with BEV (Hazard Ratio [HR]: 0.16; 95% Confidence Interval [CI]: 0.04-0.56, p = 0.004). SEV was also associated with a lower BVF risk than BEV (HR: 0.25; 95% CI: 0.08-0.76, p = 0.015). CONCLUSIONS: SEV appears to be more suitable for long-term valve durability in patients with a small aortic annulus.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Long‐Term Bioprosthetic Valve Durability After Transcatheter Aortic Valve Replacement With Supra‐Annular Self‐Expanding Versus Intra‐Annular Balloon‐Expandable Valves in Patients With a Small Aortic Annulus
- Date Crossref
- 20/01/2025
- Éditeur
- Wiley
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.