Aller au contenu principal
Accès ouvert déclaré 2024 article

Diagnostic Accuracy of Chest X-ray Computer-Aided Detection Software for Detection of Prevalent and Incident Tuberculosis in Household Contacts

11Citations signalées, ce qui n’est pas une note de qualité
13Institutions déclarées
5Pays d’affiliation déclarés

Rattachement africain : gb, ch, Afrique du Sud, us, au. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

BACKGROUND: World Health Organization (WHO) tuberculosis (TB) screening guidelines recommend computer-aided detection (CAD) software for chest radiograph (CXR) interpretation. However, studies evaluating their diagnostic and prognostic accuracy are limited. METHODS: We conducted a prospective cohort study of household contacts of rifampicin-resistant TB in South Africa. Participants underwent baseline CXR and sputum investigation (routine [single spontaneous] and enhanced [additionally 2-3 induced]) for prevalent TB and follow-up for incident TB. Three CXR-CAD software products (CAD4TBv7.0, qXRv3.0.0, and Lunit INSIGHT v3.1.4.111) were compared. We evaluated their performance to detect routine and enhanced prevalent and incident TB, comparing performance with blood tests (Xpert MTB host-response, erythrocyte sedimentation rate, C-reactive protein, QuantiFERON) in a subgroup. RESULTS: 483 participants were followed up for 4.6 years (median). There were 23 prevalent (7 routinely diagnosed) and 38 incident TB cases. The AUC ROCs (95% CIs) to identify prevalent TB for CAD4TBv7.0, qXRv3.0.0, and Lunit INSIGHT v3.1.4.111 were .87 (.77-.96), .88 (.79-.97), and .91 (.83-.99), respectively. More than 30% with scores above recommended CAD thresholds who were bacteriologically negative on routine baseline sputum were subsequently diagnosed by enhanced sputum investigation or during follow-up. The AUC performance of baseline CAD to identify incident cases ranged between .60 and .65. Diagnostic performance of CAD for prevalent TB was superior to blood testing. CONCLUSIONS: Our findings suggest that the potential of CAD-CXR screening for TB is not maximized as a high proportion of those above current thresholds, but with a negative routine confirmatory sputum, have true TB disease that may benefit intervention.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Diagnostic Accuracy of Chest X-ray Computer-Aided Detection Software for Detection of Prevalent and Incident Tuberculosis in Household Contacts
Date Crossref
18/12/2024
Éditeur
Oxford University Press (OUP)
Type
journal-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Tuberculosis Research and EpidemiologyCOVID-19 diagnosis using AIPneumonia and Respiratory Infections

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.