An automated assessment pipeline to identify prostate treatments that need adaptive radiotherapy
Rattachement africain : se, gb. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Abstract Background and purpose: This project developed and validated an automated pipeline for prostate treatments to accurately determine which patients could benefit from adaptive radiotherapy (ART) using synthetic CTs (sCTs) generated from on-treatment cone-beam CT (CBCT) images. Materials and methods: The automated pipeline converted CBCTs to sCTs utilising deep-learning, for accurate dose recalculation. Deformable image registration mapped contours from the planning CT to the sCT, with the treatment plan recalculated. A pass/fail assessment used relevant clinical goals. A fail threshold indicated ART was required. All acquired CBCTs (230 sCTs) for 31 patients (6 who had ART) were assessed for pipeline accuracy and clinical viability, comparing clinical outcomes to pipeline outcomes. Results: The pipeline distinguished patients requiring ART; 74·4% of sCTs for ART patients were red (failure) results, compared to 6·4% of non-ART sCTs. The receiver operator characteristic area under curve was 0·98, demonstrating high performance. The automated pipeline was statistically significantly (p < 0·05) quicker than the current clinical assessment methods (182·5s and 556·4s, respectively), and deformed contour accuracy was acceptable, with 96·6% of deformed clinical target volumes (CTVs) clinically acceptable. Conclusion: The automated pipeline identified patients who required ART with high accuracy while reducing time and resource requirements. This could reduce departmental workload and increase efficiency and personalisation of patient treatments. Further work aims to apply the pipeline to other treatment sites and investigate its potential for taking into account dose accumulation.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- An automated assessment pipeline to identify prostate treatments that need adaptive radiotherapy
- Date Crossref
- 01/01/2024
- Éditeur
- Cambridge University Press (CUP)
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
RaySearch Laboratories (Sweden) pays non établi dans la noticeEntreprise
-
University of Leeds pays non établi dans la noticeUniversité ou école supérieure
-
Leeds Cancer Centre pays non établi dans la noticeInstitution
RaySearch Laboratories (Sweden), University of Leeds et Leeds Cancer Centre.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.