Aller au contenu principal
2024 conference-paper

Broadband reflective spectrometer for high-resolution spectral characterization of radiation sources

1Citations signalées, ce qui n’est pas une note de qualité
3Institutions déclarées
1Pays d’affiliation déclarés

Rattachement africain : de. Niveau de preuve : code pays fourni par la source.

Le résumé fourni par la source

The development of compact radiation sources for extreme ultraviolet (EUV) radiation has enabled a multitude of lab-size applications, especially in the field of metrology, that were previously only possible at synchrotron facilities. Plasma-based and high-harmonic generation (HHG) sources are widely used and well characterized at their application specific wavelength ranges in the EUV regime. The spectrum of the emitted radiation from these sources extends to a broader wavelength range, even into the visible and infrared bands and their full spectral composition is not sufficiently characterized. Therefore, a broadband spectral characterization of the source emission is of utmost importance for the investigation of photon-induced processes and metrology. In this study, the authors present a unique setup and corresponding measurement results for the high-resolution broadband spectral characterization of radiation sources covering the extensive wavelength range from 5nm to 1μm. For the vacuum wavelength range (5nm to 200nm) the setup employs a combination of three flat-field diffraction gratings with varying line density as dispersive elements. Higher diffraction orders are filtered out by a selection of thin film filters. The wavelength range above 200nm is measured with two Czerny-Turner spectrometer modules. The resulting spectra are combined to obtain the full spectrum without any contributions from higher diffraction orders. Here, the overall design, wavelength calibration, and the relative and absolute intensity calibration of the measured spectra are presented.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.

Titre Crossref
Broadband reflective spectrometer for high-resolution spectral characterization of radiation sources
Date Crossref
21/11/2024
Éditeur
SPIE
Type
proceedings-article

Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.

Les institutions déclarées

Une affiliation ne permet pas de déduire la nationalité d’un auteur.

Les sujets associés

Calibration and Measurement TechniquesSpectroscopy and Laser Applications

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.