Adaptive Joint Data Selection for Sparsity Based Arterial Spin Labeling MRI Denoising
Rattachement africain : us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Arterial spin-labeled (ASL) perfusion MRI remains the only non-invasive, radiation-free method for quantifying regional tissue perfusion. ASL MRI computes perfusion signals from the difference of the spin-labeled images and spin-untagged control images. Limited by the T1 decay of the labeled arterial blood, ASL MRI signal is subject to a low signal-to-noise ratio. This issue is particularly vexing due to the absence of ground truth and the difficulty in preserving image textures amidst substantial noise reduction efforts. One major avenue for tackling this challenge involves leveraging the sparsity of image signals, a technique widely employed in unsupervised image denoising. Compared to global models operating at the slice level, enhanced local sparse models not only improve the separation of signal from noise but also preserves local structures more effectively. This paper introduces a joint data selection strategy tailored for ASL denoising, which capitalizes on the strong correlation between paired label and control (L/C) images to identify and assemble highly correlated content, forming potentially sparse matrices. The application of sparsity regularization to these matrices is inherently more adaptive to local structures. Crucially, the proposed method does not rely on any ground-truth training data. In real-world testing with an ASL MRI dataset, the proposed approach remarkably enhances the quality of ASL perfusion maps, utilizing only a single pair of L/C images, and outperforms the conventional pipeline that necessitates multiple L/C pairs.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Adaptive Joint Data Selection for Sparsity Based Arterial Spin Labeling MRI Denoising
- Date Crossref
- 27/05/2024
- Éditeur
- IEEE
- Type
- proceedings-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Où se fait cette recherche
-
University of Maryland pays non établi dans la noticeUniversité ou école supérieure
-
University of Pennsylvania pays non établi dans la noticeUniversité ou école supérieure
-
Perelman School of Medicine pays non établi dans la noticeUniversité ou école supérieure
University of Maryland, University of Pennsylvania et Perelman School of Medicine.
Une affiliation ne permet pas de déduire la nationalité d’un auteur.