Comparison of 3D Ultra-short Echo Time (UTE) Phase-Resolved Functional Lung (PREFUL) with Hyperpolarized 129Xe MRI in Pediatric Cystic Fibrosis
Le résumé fourni par la source
2D phase-resolved functional lung (PREFUL) MRI has been shown to correlate with hyperpolarized Xenon MRI (Xe-MRI) in pediatric Cystic Fibrosis (CF) lung disease but ventilation defects may be missed using the 2D approach. In this study we develop a 3D ultra-short echo time (UTE) PREFUL MRI method and compare to 2D PREFUL MRI and Xe-MRI in CF. 3D UTE PREFUL MRI showed a lower bias between Xe-MRI as compared to 2D PREFUL and was able to detect ventilation defects missed by the 2D approach, suggesting that the 3D approach may be a more comprehensive measure of ventilation in pediatric CF.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Comparison of 3D Ultra-short Echo Time (UTE) Phase-Resolved Functional Lung (PREFUL) with Hyperpolarized 129Xe MRI in Pediatric Cystic Fibrosis
- Date Crossref
- 14/08/2024
- Éditeur
- ISMRM
- Type
- proceedings-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.