Biolayer interferometry for adeno-associated virus capsid titer measurement and applications to upstream and downstream process development
Rattachement africain : us. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Faster and more accurate analytical methods are needed to support the advancement of recombinant adeno-associated virus (rAAV) production systems. Recently, biolayer interferometry (BLI) has been developed for high-throughput AAV capsid titer measurement by functionalizing the AAVX ligand onto biosensor probes (AAVX-BLI). In this work, an AAVX-BLI method was evaluated using Octet AAVX biosensors across four rAAV serotypes (rAAV2, -5, -8, and -9) and applied in an upstream and downstream processing context. AAVX-BLI measured the capsid titer across a wide concentration range (1 × 1010–1 × 1012 capsids/mL) for different rAAV serotypes and sample backgrounds with reduced measurement variance and error compared to an enzyme-linked immunosorbent assay (ELISA) method. Biosensors were regenerated for repeated use, with lysate samples showing reduced regeneration capacity compared to purified and supernatant samples. The AAVX-BLI method was applied in a transfection optimization study where direct capsid titer measurement of culture supernatants generated a representative response surface for the total vector genome (VG) titer. For rAAV purification, AAVX-BLI was used to measure dynamic binding capacity with POROS CaptureSelect AAVX affinity chromatography, showing resin breakthrough dependence on the operating flow rate. Measurement accuracy, serotype and sample background flexibility, and high sample throughput make AAVX-BLI an attractive alternative to other capsid titer measurement techniques. Faster and more accurate analytical methods are needed to support the advancement of recombinant adeno-associated virus (rAAV) production systems. Recently, biolayer interferometry (BLI) has been developed for high-throughput AAV capsid titer measurement by functionalizing the AAVX ligand onto biosensor probes (AAVX-BLI). In this work, an AAVX-BLI method was evaluated using Octet AAVX biosensors across four rAAV serotypes (rAAV2, -5, -8, and -9) and applied in an upstream and downstream processing context. AAVX-BLI measured the capsid titer across a wide concentration range (1 × 1010–1 × 1012 capsids/mL) for different rAAV serotypes and sample backgrounds with reduced measurement variance and error compared to an enzyme-linked immunosorbent assay (ELISA) method. Biosensors were regenerated for repeated use, with lysate samples showing reduced regeneration capacity compared to purified and supernatant samples. The AAVX-BLI method was applied in a transfection optimization study where direct capsid titer measurement of culture supernatants generated a representative response surface for the total vector genome (VG) titer. For rAAV purification, AAVX-BLI was used to measure dynamic binding capacity with POROS CaptureSelect AAVX affinity chromatography, showing resin breakthrough dependence on the operating flow rate. Measurement accuracy, serotype and sample background flexibility, and high sample throughput make AAVX-BLI an attractive alternative to other capsid titer measurement techniques.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Biolayer interferometry for adeno-associated virus capsid titer measurement and applications to upstream and downstream process development
- Date Crossref
- 01/09/2024
- Éditeur
- Elsevier BV
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.