Is mesh pore size in polypropylene meshes associated with the outcome in Lichtenstein inguinal hernia repair: a registry-based analysis of 22,141 patients
Rattachement africain : de. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
INTRODUCTION: Experimental data show that large-pored meshes reduce foreign body reaction, inflammation and scar bridging and thus improve mesh integration. However, clinical data on the effect of mesh porosity on the outcome of hernioplasty are limited. This study investigated the relation of pore size in polypropylene meshes to the outcome of Lichtenstein inguinal hernioplasty using data from the Herniamed registry. METHODS: This analysis of data from the Herniamed registry evaluated perioperative and 1-year follow-up outcomes in patients undergoing elective, primary, unilateral Lichtenstein inguinal hernia repair using polypropylene meshes. Patients operated with a non-polypropylene mesh or a polypropylene mesh with absorbable components were excluded. Polypropylene meshes with a pore size of 1.0 × 1.0 mm or less were defined as small-pored meshes, while a pore size of more than 1.0 × 1.0 mm was considered large-pored. Unadjusted analyses and multivariable analyses were performed to investigate the relation of pore size of polypropylene meshes, patient and surgical characteristics to the outcome parameters. RESULTS: Data from 22,141 patients were analyzed, of which 6853 (31%) were operated on with a small-pore polypropylene mesh and 15,288 (69%) with a large-pore polypropylene mesh. No association of mesh pore size with intraoperative, general or postoperative complications, recurrence rate or pain requiring treatment was found at 1-year follow-up. A lower risk of complication-related reoperation tended to be associated with small-pore size (p = 0.086). Furthermore, small-pore mesh repair was associated with a lower risk of pain at rest and pain on exertion at 1-year follow-up. CONCLUSION: The present study could not demonstrate an advantage of large-pore polypropylene meshes for the outcome of Lichtenstein inguinal hernioplasty.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Is mesh pore size in polypropylene meshes associated with the outcome in Lichtenstein inguinal hernia repair: a registry-based analysis of 22,141 patients
- Date Crossref
- 01/05/2024
- Éditeur
- Springer Science and Business Media LLC
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.