Supplementary Material for: Effects of extracorporeal blood flow rates on patient tolerance for LIXELLE® treatment during outpatient hemodialysis

0Citations signalées, ce qui n’est pas une note de qualité
0Institutions déclarées
0Pays d’affiliation déclarés

Le résumé fourni par la source

Introduction: Accumulation of β2-microglobulin (B2M) in dialysis patients contributes to several comorbidities of end stage kidney disease (ESKD). The LIXELLE® device adsorbs B2M from blood using sorbent bead technology. Studies in Japan showed LIXELLE treatment during hemodialysis (HD) at blood flow rates up to 250 mL/min removes B2M above HD alone and is well-tolerated. We investigated tolerance for LIXELLE treatment during HD at higher HD blood flow rates standard in the United States (US). Methods: A prospective, open-label, non-randomized, single arm, early feasibility study (EFS) assessed tolerance and safety of LIXELLE treatment during HD at blood flow rates up to 450 mL/min. ESKD patients (40-75 years old) on thrice weekly outpatient HD were eligible. After a one-week HD run-in, patients received LIXELLE plus HD at a blood flow rate of 250 mL/min (one week), followed by LIXELLE plus HD at a blood flow rate up to 450 mL/min (one week). These blood flow rates were tested with three LIXELLE column sizes in sequence (treatment = six weeks). B2M removal was assessed for each combination. Results: Ten patients with a historic intradialytic hypotension (IDH) rate of 0.42 events/HD session/patient were enrolled. Nine patients completed all combinations without IDH events (treatment IDH rate 0.56 events/HD session/patient). No treatment-emergent serious adverse events or significant changes in red blood cell, platelet, or complement indices except haptoglobin were reported. B2M reduction ratios and removal of select proteins (<40 kDa) increased with escalating column size and blood flow rate. Conclusion: LIXELLE plus HD across all column sizes was safe and well-tolerated at blood flow rates up to 450 mL/min. Extent of B2M removal corresponded to column size-blood flow rate combinations. This EFS provides a risk profile to guide further studies of LIXELLE in ESKD patients at US-standard blood flow rates.

Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.

Le contrôle bibliographique ouvert

La source scientifique ouverte est momentanément indisponible.

Les sujets associés

Dialysis and Renal Disease ManagementHemodynamic Monitoring and TherapyCentral Venous Catheters and Hemodialysis

BNTIC News n’est pas le producteur de ces données. Les publications sont interrogées à la demande dans Crossref, OpenAIRE, DOAJ, Europe PMC, HAL, DataCite, AfricArXiv, ROR et la Banque mondiale, sans clé d’accès. OpenAlex reste optionnel. Aucun service payant n’est nécessaire et aucune donnée externe n’est enregistrée en base. Consulter les sources et leurs limites.