Sedation/agitation monitoring using a wearable device for ventilated children
Rattachement africain : jp. Niveau de preuve : code pays fourni par la source.
Le résumé fourni par la source
Abstract Background Developing continuous and labor‐saving sedation/agitation monitoring methods in ventilated children is important to avoid undesirable events such as unplanned extubation. The existing scales are often challenging to use. We therefore aimed to evaluate the feasibility of sedation/agitation monitoring using a wearable device with a built‐in accelerometer for ventilated children. Methods This prospective observational pilot study included children aged 15 years or less, admitted to the pediatric intensive care unit on mechanical ventilation after cardiac catheterization between December 2021 and April 2022. The wearable device with a built‐in accelerometer was attached to either of the upper limbs, and accelerations due to upper limb movements were measured for 2 h after admission or until extubation, whichever was earliest. Accelerations were measured at 0.02 s intervals, with the mean acceleration calculated for each 1 min interval. The State Behavioral Scale (SBS) was completed at 1 min intervals, with the SBS score (−1, 0, 1, or 2) compared with the mean acceleration. Results The study included 20 children with a median age of 12 months. The mean accelerations and SBS scores were positively correlated (Kendall's τ, 0.22; p < 0.001), with an increase in the median (interquartile range) acceleration from an SBS score of −1 through 2, as follows: SBS −1, 0.200 (0.151–0.232) m/s2; SBS 0, 0.202 (0.190–0.235) m/s2; SBS, 1, 0.312 (0.236–0.427) m/s2; SBS 2, 0.455 (0.332–0.517) m/s2. No adverse events were observed. Conclusions This study showed that continuous, labor‐saving sedation/agitation monitoring of ventilated children was feasible using a wearable device with a built‐in accelerometer.
Ce résumé expose les affirmations des auteurs. BNTIC ne l’interprète pas comme une validation indépendante des résultats.
Le contrôle bibliographique ouvert
DOI retrouvé dans Crossref DOI retrouvé ; titre concordant.
- Titre Crossref
- Sedation/agitation monitoring using a wearable device for ventilated children
- Date Crossref
- 01/01/2023
- Éditeur
- Wiley
- Type
- journal-article
Ce recoupement confirme des métadonnées liées au DOI. Il ne confirme ni la méthode ni les conclusions de l’étude, et il ne compte pas comme une seconde source scientifique indépendante.
Les institutions déclarées
Une affiliation ne permet pas de déduire la nationalité d’un auteur.